30
11.
Total (M+) Function
11.1.
Total (M+) Function
The scale can accumulate count data manually (by pressing the M+ key) or automatically.
The number of pieces accumulated and the number of additions (how many times the total was added
to) can be viewed with the TOTAL key.
Adding Data Manually (by pressing the M+ key)
1. When the weighing value is stable (stable mark is lit),
press the M+ key. The scale accumulates the
number of pieces that have been counted, and the
M+ mark blinks for a few seconds.
2. Remove counted pieces from the weighing pan. The scale cannot continuously add the same data.
Before the next addition, the scale needs to return to near zero.
When the scale has accumulated data, the M+ mark lights up.
If the scale beeps four times and the M+ mark does not blink, refer to the following note.
The M+ key is usually accepted only once normally when positive count data is
stable. Once accepted, the next accumulation cannot be done until the scale returns to
near zero.
The scale cannot accumulate data at near zero.
If function setting
is set to “ ”, the M+ key can accumulate even negative
data. In this case as well, the next accumulation cannot be done until the scale returns
to near zero.
Even if data is accumulated to the total value called up from the memory, the total value
in the memory is not updated. To store it in the memory, follow the procedure described
in “
11.5. Calling Up Unit Weight and Total Count Together
Erasing the Last Added Data
1. Hold down the C key and press the M+ key.
2. Only the one data instance that was added last is erased from
the total value.
If the scale beeps four times, it indicates there is no data to
be erased.
Automatic Accumulation
The number of pieces counted can be automatically accumulated. When the weighing value is stable
(when the stable mark is lit), the number is automatically accumulated and the scale beeps one time.
For the next accumulation, remove counted pieces so that the scale returns to near zero.
To use automatic accumulation, set function setting
to “ ”.
Automatic accumulation is operable with positive count data only. Even if function setting
is
set to “ ” (Accept positive/negative data), the negative count data is not accumulated.
Hold down the
key
and press the
key