AD4412-CW
23
Fig. 37
DO2 operation setting screen
5. Return to the DO setting screen and touch the AD-4412-CW button to display the DO operation setting screen.
6. In this example, DO does not need to be set for the belt conveyor and tower light. However, when using a flipper, etc,
set the delay time as “the time until the weighing product reaches the rejecter after detecting it at the end of the
conveyer” plus "the swing time for the flipper of the rejecter”.
(However, the swing time for the flipper of the rejecter varies depending on settings for the cushion needle of the air
cylinder. So, fine adjustment is required for it.)
7. Hold time is the time to output the signal. There is a possibility that a jitter of about 50msec is generated at the hold
time. So, it must be set with sufficient leeway.
If DI connection is made for other external equipment, see "9.13. DI (Digital Input)" in the instruction manual.
Fig. 36
DO setting screen