AD-4410
Page
20
Select positive logic or negative logic using
fncf13
(logic output for upper and lower
limits)
6.1.9. Hold function
There are three types of hold functions which can be used for different purposes.
1. Normal hold
Holds the value displayed at the time the hold command was received.
2. Peak hold
Holds the maximum value reached after the hold command was received.
The value will be refreshed if it increases again.
3. Averaging hold
This function averages weighing data over a certain period of time and then holds the
result.
It is useful for measuring things that are difficult to weigh such as an animal that won’t
settle down, or for averaging out the weight of an object in an unstable state. In
addition, it can reduce the effects of breezes which the digital filter cannot eliminate.
Related functions
- To select the type of hold function:
Select the type of hold function with
fncf07
(hold)
- To set operating conditions for the hold function:
Set the averaging time length, standby time, or start and stop conditions with
Hldf01
to
07
. (Will not affect normal holds)