Solution: Investigate damage to filters and replace as necessary. Investigate
cause and consider replacement AAF filters with a higher temperature
rating.
12.3
Insufficient Airflow
Issue:
Filters are clogged, or dirty causing loss of airflow.
Solution: Confirm pulse operation is occurring normally. Replace filters with a
new set of filters.
Issue:
Fan running backwards
Solution: When power is disconnected, switch wiring on terminals to motor. Fan
wheel should spin the direction marked on the motor. Consult wiring
diagram for additional details.
Issue:
Fan Vibration or Motor Over-Amping
Solution: Shut unit power off. Contact AAF Technical Support and Fan and/or
Motor Manuals for more information.
13
RECOMMENDED SPARE PARTS LIST
Item
Description
Recommended
On Hand Spares
1
2
3
4
5
Lid Gasket
Diaphragm Valve Repair Kit
Solenoid Valve Repair Kit
REDClean Filters
Pulse Controller
1
1
1
6
1