12
© 2016 American Air Filter Company, Inc. Any use of the text or images
this document contains, without permission of American Air Filter
Company, Inc., is prohibited. FabriPulse and AAF are registered
trademarks of American Air Filter Company, Inc. d/b/a AAF
International.
6.2
Handling
Only personnel experienced in handling equipment shall be employed for this
task.
It is recommended that each item of equipment remain on its pallet until it
has been moved to its final installation location. The FabriPulse BinVent may be
moved using a forklift to lift the product using its shipping pallet, if available. If
lifted by its shipping pallet, attention must be paid to properly balance the load
and strapping it to the handling device. Care shall be taken to ensure that the
equipment is not dropped or subjected to any impact loads.
6.3
Rigging and hoisting instructions
Only personnel experienced in rigging and hoisting equipment shall be
employed for this task.
The FabriPulse BinVent has lifting lugs mounted on the sides of the unit.
These may be used to hoist the product into its installation position. All lifting lugs
must be used when hoisting the product, spreader bars must be used at all times.
Position the spreader bars so that the force applied to each lifting lug is vertical
and not angled. Also make sure that lifting straps or cables do not come into
contact with any other part of the product to prevent the possibility of damage
from abrasion. Before hoisting, make sure that the load is properly balanced.
7
STORAGE AND PROTECTION
In the event that the equipment is not placed in service within 30 days after
receipt, the filter cartridges must be removed and stored in a clean, dry place to
prevent possible moisture accumulation in the media.
8
SITE PREPARATION
8.1
Locating equipment
The dust collector site location must take into account the wind and seismic
loadings. See collector specifications to ensure proper site location.
Ensure local laws, codes and regulations are followed for the materials being
collected. Noise levels should be considered when selecting the proper location of
the FabriPulse BinVent.
Locate the FabriPulse BinVent in a location so that maintenance to the collector
can be handled easily. See collector drawing for cartridge clearance.