FabriPulse BinVent

 
 
 

 
 

 

 

 

Summary of Contents for FabriPulse BinVent

Page 1: ...nc Any use of the text or images this document contains without permission of American Air Filter Company Inc is prohibited FabriPulse and AAF are registered trademarks of American Air Filter Company...

Page 2: ...is prohibited FabriPulse and AAF are registered trademarks of American Air Filter Company Inc d b a AAF International TO ORDER SPARE REPLACEMENT PARTS Call 1 800 477 1214 Email APCSales AAFINTL com P...

Page 3: ...6 Safety guards 8 3 GENERAL PRODUCT INFORMATION 8 3 1 Description 8 3 2 Purpose and intended use 8 3 3 Normal Operation 9 3 4 Sizes 9 3 5 Filter elements 9 3 6 Weights 10 4 PRODUCT SHIPMENT 10 4 1 Ho...

Page 4: ...9 2 Filter Installation 13 9 3 Fan Installation 15 9 4 Electrical Connections 15 9 5 Compressed Air Connection 18 10 START UP OPERATION 18 10 1 Start up checklist 18 10 2 Normal operation 18 11 MAINTE...

Page 5: ...l relevant local state and federal government codes laws and policies 2 SAFETY 2 1 Safety statement The air cleaning equipment supplied by AAF International ranges from very large multiple component a...

Page 6: ...rea impedes into existing access ways or traffic routes for which no practical alternative is available barriers wardens and flaggers shall be employed to safely control crossing traffic and personnel...

Page 7: ...ystems are supplied by multiple vendors it is the responsibility of the user to coordinate between suppliers to ensure that the equipment supplied by each vendor will work together to achieve the requ...

Page 8: ...hen ordered with fan option the FabriPulse BinVent will be supplied with a fan outlet guard to help prevent access to the fan from the outside of the unit Additionally the housing should never be ente...

Page 9: ...econds blowing collected dust off the filter element s Gravity returns the particulate to the process stream below 3 4 Sizes The FabriPulse BinVent is built around a round vertical hanging cartridge t...

Page 10: ...tems that ship separately AAF International may ship items separately The customer will be notified which equipment ships separately Items that ship separately should be set aside in an area that is c...

Page 11: ...iscernable Digital color photographs must be taken of any damage to the packaging and the equipment immediately on discovery The nature of any damage must also be documented in writing Adequate docume...

Page 12: ...ay be used to hoist the product into its installation position All lifting lugs must be used when hoisting the product spreader bars must be used at all times Position the spreader bars so that the fo...

Page 13: ...cal installation laws codes regulations and procedures are followed A qualified installation and service agent must complete installation and service of the dust collector and equipment Ensure all cov...

Page 14: ...merican Air Filter Company Inc d b a AAF International 2 To secure the lid in the open position engage the locks via the latches on the side at the rear of the unit as show below 3 Open the hold down...

Page 15: ...e with the drawings provided with your order Mount the fan as shown on the drawing on the fan platform Connect the fan to the flexible inlet boot and clamp the boot to the fan and collector using the...

Page 16: ...any Inc d b a AAF International If a fan is provided with the collector the fan requires field wiring and power by the customer The supplied fan requires 3 phase 208 230 460V connection A fan stop inp...

Page 17: ...ard setting is between 150 and 250 milliseconds 3 Press Select to confirm the setting To set the time between pulses enter programming mode and press Select when the Off Time LED is lit 1 The LED shou...

Page 18: ...lable should be 90 100 psig Check that the filters are properly installed and that the round knob on the hold down mechanism is locked in place see section 9 2 Energize the pulse controller and ensure...

Page 19: ...ervals are recommendations by AAF your dust collection system may need more or less frequent maintenance plans 11 2 Six months Examine the filters for any wear damage or excessive deposition of dust I...

Page 20: ...rces before servicing CAUTION Dirty cartridges may be heavy use caution when removing the cartridges from the dust collector Do not operate the dust collector with missing or damaged filters The worki...

Page 21: ...filters 9 Drop in new filters into the openings Ensure flange of the filter is flush against the panel 10 Close hold down latch and push and turn round knobs 90 degrees to lock in place 11 Close lid a...

Page 22: ...ue Static electric charge effects may occur with very highly electrically resistant dusts and in very dry applications Solution Switch to AAF antistatic filters Issue Non standard filters used Solutio...

Page 23: ...dirty causing loss of airflow Solution Confirm pulse operation is occurring normally Replace filters with a new set of filters Issue Fan running backwards Solution When power is disconnected switch wi...