112
Problem
(Graphics) application software does not display correctly on the CRT or LCD
display.
Answer
8
Return to DOS and reboot the system and reload the operating software.
8
Check the installation instructions of the application software; select a video
mode and resolution that is supported the monitor or LCD display.
8
Restart the (graphics) application software.
Problem
After installation of a new display driver under MS-Windows the monitor or
LC-display does not operate properly.
Answer
8
Return to DOS and reboot the system.
8
Change into the MS-Windows directory.
8
Start the MS-Windows Setup-Program and select the standard VGA display
driver for your system.
8
Quit the Setup-program.
8
Install a display driver for the PCM-4330 board (see section 2.4.1 on page 35)
that uses a video mode and resolution that is supported by your monitor or
LC-Display (see Appendix B: LC-Displays).
Problem
You have selected a higher display resolution under MS-Windows using the West-
ern Digital Display Changer. However, the display resolution is still unchanged.
Answer
8
Please check the settings of the configuration switches.
8
If you are using a CRT display only, make sure that switch SW.2 of the configu-
ration switches is set to on.
8
If you are using a simultaneous display on a CRT and LC display, the settings of
switches SW.3 to SW.8 limit the maximum display resolution possible. You
can not select a higher resolution than selected for the display.