![background image](http://html1.mh-extra.com/html/aaeon/mix-kluw1/mix-kluw1_manual_3306997035.webp)
3-7
Chapter 3: BIOS setup
The following item appears only when you set
Fan Control Mode
to [Manual
Mode].
PWM/DC Voltage Output [255]
Sets the voltage allocated for Fan Control. Input value range: [0~255]
The following items appear only when you set
Fan Control Mode
to [Thermal
Cruise Mode].
Target Temperature [50]
Input value range: [0~127]
Tolerance of Temperature [0]
Input value range: [0~7]
Fan Out Start-Up Value [127]
Input value range: [0~255]
Fan Stop Duty [Down to 0]
Configuration options: [Down to 0] [To Fan Out Stop Value]
Fan Out Stop Value [100]
The Fan Out value decreases to this value if the temperature reaches below
the lowest temperature limit. Input value range: [0~255]
Fan Out Stop Time [60]
Determines the amount of time it takes for the Fan Out value to fall from the
stop value to zero. Input value range: [0~255]
Critical Temperature [75]
Determines the amount of time Fan Out takes to decrease its value by one
step. Input value range: [0~255]
Fan Out Step Up Time [10]
Determines the amount of time Fan Out takes to increase its value by one
step. Input value range: [0~255]
Fan Out Step Down Time [10]
Determines the amount of time Fan Out takes to decrease its value by one
step in intervals of 0.1 seconds. Input value range: [0~255]
3.3.8
USB Configuration
The items in this menu allow you to change the USB-related features.
The USB Devices item shows the auto-detected values. If no USB device is
detected, the item shows
None
.