2.
Technical Parameters
2.1
Specifications
•
Model:
CH-PFC1215, for 4 cells pack,
•
Input Voltage:
96 to 260 VAC
•
Max. Output Voltage:
14.2V (3.55V/cell)
•
Maximum Output:
15A
•
Power factor:
≥99%
•
Efficiency:
≥92%
•
Input voltage range:
AC 85 ~ 242V
•
Frequency range:
45 ~ 65Hz
•
Communication:
CAN and 12V Digital Input
2.1
Operating Environment
•
Altitude:
≤2000 Meters
•
Temperature:
-35°C ~ 65°C
•
Storage environment:
-40°C ~ 100°C – Keep away from combustible materials
•
Vibration:
SAEJ1378
•
Water resistance:
IP31
•
Installation Stress:
≤ level 5
•
Humidity:
5% ~ 70% RH – Non Condensing, keep away from exposure to moisture
3.
Charging Status and Alarm Status Indication
3.1
1 Alarm Indication
•
Reverse polarity or low voltage:
light blinking, 20% light on
•
Charger over heating:
light blinking, 40% light on
•
Ambient temperature too high:
light blinking, 60% light on
•
Charging time out:
light blinking, 80% light on
•
Over Voltage Protection:
light blinking, 100% lights on
•
BMS alarm/charging interruptions
All LED’s blinking
3.2
Charging Status Indication
•
Shutdown status:
Six lights blinking
•
Charging stage:
Percent light indicating pack voltage vs. max charging
-
voltage
•
Battery presence not detected:
Red light blinking, 20% light on
•
Charging complete:
All green lights on