background image

 

 

 

TUBE CONNECTION AND START UP: 

 

Connect silicone tube (if you use oxygen generator or oxygen tank or external air compressor) to 

ozone generator (Air IN) and direct it away from hot and humid air to the ozone cell. This will 

serve as oxygen, or fresh air for ozone production. 

Connect ozone generator PTFE tube (OZONE OUT) to venture injector manifold. 

Install a check valve 10 inches after ozone out let tube fitting (even the venturi has internal 

check valve). You may do this by cutting tube ten inch after OZONE out fitting. Connect both 

ends of cut tubes to the check valve. Please direct the arrow on the check valve toward venturi. 

START, first the swimming pool water re-circulation pump. Make sure you have vacuum at the 

venturi via a gauge and test it by putting your finger on the venturi opening. You should feel a 

small suction, this is what is needed to get the ozone production out of the unit and inject it into 

the pool piping system. Check Flow meter, air flow should indicate at least 2 LPM. Now connect 

the PTFE tube from the venturi to the ozonator and turn on the power in the internal panel of 

ozone generator. 

The ozone indicator light up and the fan should turn on. Increase power to the Cells by turning 

the ozone control knob clockwise.  Please refer to the charts above for the approximate ozone 

concentration for your size of pool. 

 

OZONE GENERATOR OPERATION 

System Running Time  

On residential pools, the ozone generator should operate for six to eight hours per day. 

Normally, the ozone system will run whenever the pool filtration system is operating. Since 

commercial pool and spa filtration systems normally operate 24 hours a day, the ozone system 

will run continuously on a commercial pool.  

Understanding Your Water 

If a high concentration of any mineral (such as calcium or iron) exists in the water, it is necessary 

to treat it before starting the ozone system. 

Note: This should be required only when the pool is drained and refilled.  

 

If the water is clean and clear, the ozone system may be started immediately. If the water is 

dirty 

and 

cloudy, it is recommended that it is drained and the filters thoroughly cleaned before 

refilling and starting the system.  
Note: It is not recommended that an in-ground pool be drained in the winter or after the first 

rain of a season. Use a shock treatment instead of draining to avoid the possibility of severe 

damage resulting from “floating” the pool out of the ground.  

 

Ozone and Bromine  

Ozone has a short “half-life”, which means it dissipates and re-transforms into oxygen very 

quickly. Therefore, a 

small 

residual of

 

another disinfectant must be maintained. We recommend 

the use of bromine in indoor pools. Bromine residual will act as a buffer when the ozone system 

Summary of Contents for SP-3

Page 1: ...A2Z OZONE INC OWNER S MANUAL SWIMMING POOL OZONE GENERATOR MODEL SP Series 110 or 220 240VAC 50 60Hz A2Z OZONE INC 1844 Cargo Court Louisville KY 40299 USA www A2Zozone com...

Page 2: ...N AND START UP o USING OXYGEN BOTTLE TANK o USING OXYGEN GENERATOR o USING EXTERNAL AIR COMPRESSOR MAINTENANCE PROCEDURES FUSE CLEAN FAN SCREEN CLEAN OZONE TUBE CONTROL PAN L CONNECTION FITTING TROUBL...

Page 3: ...l supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with Section 422 20 of the National Electrical Code ANSI N FPA 70 1...

Page 4: ...ol ozone from 10 100 concentration Use the AMP meter to see any possible defaults Observe the Air Flow meter if venturi has enough flow to create vacuum and inject ozone into water pipe line The Air F...

Page 5: ...time then water circulating rate should be once each 3 to 4 hour period The pump should re circulate the total volume of pool water through the injector at least once each 4 hr period for maximum lit...

Page 6: ...e to the ozone injection point Situate the unit in a manner suitable for convenient electrical access The MODEL SP SERIES enclosures is not rain proof so it is important to choose a location that will...

Page 7: ...ri input Note1 Use the installed flow meter to check vacuum 2 to 3 PSI 0 14 to 0 21 bars or place finger over end of venturi valve to feel vacuum while adjusting the by pass venturi valve At this poin...

Page 8: ...fer to the charts above for the approximate ozone concentration for your size of pool OZONE GENERATOR OPERATION System Running Time On residential pools the ozone generator should operate for six to e...

Page 9: ...ays maintain the recommended residual levels of bromine or chlorine at least 1 0 PPM to help control algae formation Brushing poolside once a week is also effective as is any algaecide Shock Treatment...

Page 10: ...er clean will make a noticeable difference in the clarity of the water It is recommended that a regular filter cleaning schedule is established or poor water flow through the filter will result This w...

Page 11: ...ation lamp is lit B Check ozone control knob is set above zero C Check ozone board fuse 3 AMP D Check wire from terminal to ozone board E Check Pot wire is connected to ozone board If you are still ex...

Page 12: ...12 SAMPLE SCHEMATIC DIAGRAM...

Page 13: ...vel of safety In contrast to ultraviolet ozone generators corona discharge systems produce a much higher concentration of ozone and in much larger quantities In addition the annual expense of replacin...

Page 14: ...used to concentrate oxygen out of air When pure oxygen is used a higher concentration of ozone can be produced 4 How does ozone work Ozone operates according to the principle of oxidation Ozone is fas...

Page 15: ...into the water Ozone is a gas and it is only slightly soluble in water It must be thoroughly dissolved in water so that the chemical reactions with contaminants can take place The most common way in s...

Page 16: ...n other words before ozone could possibly have any unsafe effects a person would be greatly offended by its bleach like odor Ozone is safe to use in occupied areas because we notice its unpleasant odo...

Page 17: ...eave in your pool When these particles are oxidized they form visible particles that are heavier than water and precipitate Also there will be pieces or fragments of the cells that ozone has destroyed...

Page 18: ...sed The longer the ozone operates each day the greater the reduction in chemical sanitizers Pool owners have had reductions in sanitizer use of 50 to 90 Your savings may vary based on pool usage facto...

Page 19: ...ractices d ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND SUCH WARRANTIES ARE HEREBY DISCLAIMED AND e A2Z Ozone SHALL NOT BE LIABLE UNDER ANY CIRCUMS...

Page 20: ...________________ Dealer Info Dealer Name______________________________ Dealer Address_______________________________________________________ City_________________________________State_________Zip_____...

Page 21: ...21...

Reviews: