background image

 

CAUTIONS AND GENERAL NOTES 

 

This manual covers the 

SWIMMING POOL OZONE GENERATOR MODEL SP-Series 

Corona 

Discharge (CD) Ozone Generators. A2Z Ozone Systems Inc. reserves the right to make changes to 

the product covered in this manual to improve performance, reliability, or manufacturability. 

Make sure that this manual is used with the original product it was shipped with. Although every 

effort has been made to ensure accuracy of the information contained in this manual, A2Z 

Ozone Systems assumes no responsibility for inadvertent errors. 

 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

PLEASE READ AND FOLLOW ALL INSTRUCTIONS. 

 

Read this manual completely before attempting installation and/or operation. 

 

Install in accordance with the installation instructions. 

 

Connect to a grounded, grounding type receptacle only. 

 

Warning 

- To reduce the risk of electrical shock, replace damaged electrical cable immediately. 

 

Follow all applicable electrical codes. 

 

Electric shock hazard. Be sure to turn power OFF and disconnect from power source 

before any Service work is performed. Failure to do so could result in serious injury or 

death.

 

A licensed, qualified electrician should make all electrical connections. 

 

Install the ozone generator at least five feet from the water using nonmetallic plumbing. 

 

Install ozone check valves to prevent water from contacting the electrical equipment. 

 

The electrical supply for this product must include a suitably rated switch or circuit 

breaker to open all ungrounded supply conductors to comply with Section 422-20 of the 

National Electrical Code, ANSI/N FPA 70-1987. The means of disconnecting the 

equipment must be readily accessible to the operator(s) but installed at least five feet 

from the water. 

 

Ambient temperature around the equipment should be between 40 and 100 Deg. F (4.5 

to 38 Deg. C). If the equipment is installed in an environment with temperatures over 

100 Deg. F, additional air cooling must be provided. Installation without additional air 

cooling in an environment where temperatures exceed 100

 

Deg. F for any continuous 24 

hour period will void the warranty. 

 

The system should be sized appropriately for its intended use by a qualified professional 

familiar with the application. The manufacturer for its intended use must validate this 

equipment. 

 

Warning -

 Short term inhalation of high concentrations of ozone and long term inhalation of low 

concentrations of ozone can cause serious harmful physiological effects. 

DO NOT 

inhale ozone 

Gas produced by this device. 

 

For your safety, do not store or use gasoline, chemicals or other flammable liquids or 

vapors near this or any other appliance. 

 

A spontaneous and violent ignition may occur if oil, grease or greasy substances come in 

contact with oxygen under pressure. These substances must be kept away from oxygen 

regulators, cylinder valves tubing and connections, and all other oxygen equipment. 

 

IT’S HIGHLY RECOMMENDED TO SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE! 

 

Summary of Contents for SP-3

Page 1: ...A2Z OZONE INC OWNER S MANUAL SWIMMING POOL OZONE GENERATOR MODEL SP Series 110 or 220 240VAC 50 60Hz A2Z OZONE INC 1844 Cargo Court Louisville KY 40299 USA www A2Zozone com...

Page 2: ...N AND START UP o USING OXYGEN BOTTLE TANK o USING OXYGEN GENERATOR o USING EXTERNAL AIR COMPRESSOR MAINTENANCE PROCEDURES FUSE CLEAN FAN SCREEN CLEAN OZONE TUBE CONTROL PAN L CONNECTION FITTING TROUBL...

Page 3: ...l supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with Section 422 20 of the National Electrical Code ANSI N FPA 70 1...

Page 4: ...ol ozone from 10 100 concentration Use the AMP meter to see any possible defaults Observe the Air Flow meter if venturi has enough flow to create vacuum and inject ozone into water pipe line The Air F...

Page 5: ...time then water circulating rate should be once each 3 to 4 hour period The pump should re circulate the total volume of pool water through the injector at least once each 4 hr period for maximum lit...

Page 6: ...e to the ozone injection point Situate the unit in a manner suitable for convenient electrical access The MODEL SP SERIES enclosures is not rain proof so it is important to choose a location that will...

Page 7: ...ri input Note1 Use the installed flow meter to check vacuum 2 to 3 PSI 0 14 to 0 21 bars or place finger over end of venturi valve to feel vacuum while adjusting the by pass venturi valve At this poin...

Page 8: ...fer to the charts above for the approximate ozone concentration for your size of pool OZONE GENERATOR OPERATION System Running Time On residential pools the ozone generator should operate for six to e...

Page 9: ...ays maintain the recommended residual levels of bromine or chlorine at least 1 0 PPM to help control algae formation Brushing poolside once a week is also effective as is any algaecide Shock Treatment...

Page 10: ...er clean will make a noticeable difference in the clarity of the water It is recommended that a regular filter cleaning schedule is established or poor water flow through the filter will result This w...

Page 11: ...ation lamp is lit B Check ozone control knob is set above zero C Check ozone board fuse 3 AMP D Check wire from terminal to ozone board E Check Pot wire is connected to ozone board If you are still ex...

Page 12: ...12 SAMPLE SCHEMATIC DIAGRAM...

Page 13: ...vel of safety In contrast to ultraviolet ozone generators corona discharge systems produce a much higher concentration of ozone and in much larger quantities In addition the annual expense of replacin...

Page 14: ...used to concentrate oxygen out of air When pure oxygen is used a higher concentration of ozone can be produced 4 How does ozone work Ozone operates according to the principle of oxidation Ozone is fas...

Page 15: ...into the water Ozone is a gas and it is only slightly soluble in water It must be thoroughly dissolved in water so that the chemical reactions with contaminants can take place The most common way in s...

Page 16: ...n other words before ozone could possibly have any unsafe effects a person would be greatly offended by its bleach like odor Ozone is safe to use in occupied areas because we notice its unpleasant odo...

Page 17: ...eave in your pool When these particles are oxidized they form visible particles that are heavier than water and precipitate Also there will be pieces or fragments of the cells that ozone has destroyed...

Page 18: ...sed The longer the ozone operates each day the greater the reduction in chemical sanitizers Pool owners have had reductions in sanitizer use of 50 to 90 Your savings may vary based on pool usage facto...

Page 19: ...ractices d ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND SUCH WARRANTIES ARE HEREBY DISCLAIMED AND e A2Z Ozone SHALL NOT BE LIABLE UNDER ANY CIRCUMS...

Page 20: ...________________ Dealer Info Dealer Name______________________________ Dealer Address_______________________________________________________ City_________________________________State_________Zip_____...

Page 21: ...21...

Reviews: