11
Please make sure water will not back into the Aquatic 2 Spa Ozone Generator. Water will
damage the unit and void the warranty.
Please check these:
• Install the Aquatic 2 above water level and as high as possible.
• Mount the unit so the tube, light and wires are toward the ground (disregard front label).
• Install the check valve according to the arrow on the check valve (arrow is toward the
injector).
• You need an injector for injecting ozone into the spa’s water line.
• If you do not have a venturi injector, please contact us for purchasing one.
• This unit does not work without an injector.
• There should be a vacuum at ozone injector suction location.
• This can be felt with your finger when installing.
• Ozone generator should be on only when the spa pump is on.
• If your spa did not have an ozonator, then connect ozone electric wire to pump wires.
Operating Instructions