9
9
IP address settings (continued)
Setting new static IP address in
the ETX-200
Connect your PC to each EXM
unit after that you have done all
other settings in the units and
change to a specific IP address
for every unit.
A recommendation is to use from
192.168.0.21 and higher.
NOTE!
Almost every switch/router
use 192.168.0.1 as default IP
address so make sure you don’t
use the same IP address in any
ETX-200 unit.
To continue settings press [Input]
4.3.3 Tuner settings
Select the bandwith of the channel
you want to receive. Next select
the channel number according to
CCIR or enter the correct
frequency (in MHz). Be sure to
press [Set] to enter the frequency
to the ETX-200.
A list of the available services
from the multiplex you tuned to,
will be shown on the right hand
side.
Below [Tuner settings] information
of the received signal is displayed.
If only ASI in is used you can
Disable the tuner
Note!
We recommend that the
[Level] reading is better than -55
dBm and C/N better than 25 dB for
best performance.
4 Settings (continued
)