A/S WODSCHOW & CO

Industrisvinget 6

DK-2605 Broenby

www.bearvarimixer.dk

Page

Previous page
Next page

Number of pages:

Last printed:

Last corrected:

Page rev.:

Project rev.:

/

Appr. (init/date):

/

Const. (project/page): 

Drawing no.: 

Subject name: 

Project title:

File name:

 

Page title: Main Power

1

1

10-06-2011

10-06-2011

VL1, 3 x 380 - 480V AC + PE

VL1-3P-PE

L1

L2

L3

M

3

-M1

PE GN

YE

U1 BK

V1 GY

W1 BN

-F1

1

2

3

4

5

6

/4

/8

-K1

1

2

3

4

5

6

/8

PE

-F1

98

97

/2

-K1

13

14

/8

/2

-K1

/2

/5

-PCB

18

17

/5

-PCB

19

20

21

22

2 N

1 L1

/8

/8

PE

-G1

-PCB

/5

16

15

96

95

21

22

1

2

-CE

-F1

/2

PE

1

2

1

2

-S1

-F3

-F2

6,0-9,2A

400VAC

230VAC

-T1

Main Motor

Thermo Relay

Motor protection

Contactor

Main Motor

Emergency stop

Contactor

Main Motor

Operator

Panel

Operator

Panel

Operator

Panel

-K1

Hold

-F2

Thermal Relay

230VAC/50Hz

Supply

Safety guard

safety micro

Start

Start

Stop

Stop

3 x 380-480V AC + PE

Power supply

Max. 16A

Customer supplied

Fuse

500V/1A

Fuse

250V/1,5A

Fuse

500V/1A

Fuse

250V/1,5A

safety micro (CE)

 

Trafo

0

1

2

3

4

5

6

7

8

9

A/S WODSCHOW & CO

Industrisvinget 6

DK-2605 Broenby

www.bearvarimixer.dk

Page

Previous page
Next page

Number of pages:

Last printed:

Last corrected:

Page rev.:

Project rev.:

/

Appr. (init/date):

/

Const. (project/page): 

Drawing no.: 

Subject name: 

Project title:

File name:

 

Page title: Main Power

1

1

10-06-2011

10-06-2011

VL1, 3 x 200 - 240V AC + N+ PE or 2x230V AC + PE

VL1-1P-N-PE OR 2P+PE

L1(N)

L2

PE

M

3

-M1

PE GN

YE

U1 BN

V1 BU

-F1

1

2

3

4

5

6

/5

/8

-K1

1

2

3

4

5

6

/8

-F1

98

97

/2

-K1

13

14

/8

-K1

/2

/5

-PCB

18

17

/5

-PCB

19

20

21

22

2  N

1  L1

/8

/8

-G1

-PCB

/5

16

15

96

95

21

22

1

2

-CE

-F1

/2

PE

1

2

1

2

-S1

-F2

6,0-9,2A

Main Motor

Thermo Relay

Motor protection

Contactor

Main Motor

Emergency stop

Contactor

Main Motor

Operator

Panel

Operator

Panel

Operator

Panel

-K1

Hold

-F2

Thermal Relay

230VAC/50Hz

Supply

Safety guard

safety micro

Start

Start

Stop

Stop

1 x 200-240V AC + N+ PE

or 

2 x 230V AC + PE 

Power supply 

Max. 16A

Customer supplied

Fuse

250V/1,5A

Fuse

250V/1,5A

safety micro (CE)

 

Summary of Contents for AR80

Page 1: ...odschow Co Kirkebjerg Søpark 6 DK 2605 Brøndby Phone 45 43 44 22 88 info wodschow dk www bearvarimixer dk Denmark AR80 122016 ORDER NO 00333 VL 1 GB Translation of the original user manual OPERATING INSTRUCTIONS ...

Page 2: ...ion overloading and lacking observance of direc tions of maintenance It should be checked that all loose parts are delivered with the mixer such as bowl tools grease gun and rub ber feet If the mixer has an attachment drive only equipment produced by A S WODSCHOW CO must be con nected Safety The constant noise level of the workplace of the operator is lower then 70 dB A The mixer is designed for m...

Page 3: ...100 40 1 kgs If for instance it is required to use the maximum capacity of the mixer the calculated AR 60 is used for determining the amount of solids and liquid in the dough If a 80 L mixer is used and a dough with AR 60 is to be kneaded the maximum capacity is 60 kg Now the weight of solids in this dough is calculated Solids Max capacity x100 60 kg x 100 37 5 kg AR 100 60 100 Weight of liquid 60...

Page 4: ...st be moved back to lowest speed fig 4 H Stop the mixer by pressing fig 1 Start up after stop at high speed This procedure is used in all cases where the mixer has been interrupted at high speed either because the mixer has been stopped using the mixing time has run out the emergency stop is activated or the safety guard is opened 1 Lower the bowl and remove the tool from the bayonet 2 Raise the b...

Page 5: ...cker wires should be used alternatively use the beater and the whip Cleaning The mixer should be cleaned daily or after use The mixer should be cleaned with a soft cloth and clean water Sulphonated soaps should be used with caution as they destroy the mixer s lubricants Never use high pressure cleaning for the mixer Parts made of aluminum should not be used to strongly acidic highly alkaline or hi...

Page 6: ...al V belt A by moving one or two washers from V to T 3 Start the mixer and leave it running while the nut U is tightened Do not tighten it too much 4 On the front pulley set the stud E on the varispeed collar F must be placed inside the lower fork G and on the rear pulley set outside the fork for belt tightener B both must point backwards 5 Tolerances in the transmission might cause that the speci...

Page 7: ...djusting diameter Y AR80 516 mm In case the bowl fastening is too loose remove the lock ring B and draw the bearing A from the shaft C The bearing should be turned 180o and be mounted on the shaft again It might be necessary to turn both bearings At last check the bowl centering and if necessary adjust Adjustment of bowl height The distance X is measured from the bottom side of the bayonet hole to...

Page 8: ... motor will stop and will be shown for overheat in the display Allow the mixer to cool down After a short time the display will change to normal mode The mixer can be started again See also the section Start up after stop at high speed on page 4 ...

Page 9: ... Start Start Stop Stop 3 x 400V AC N PE Power supply Max 16A Customer supplied 0 1 2 3 4 5 6 7 8 9 A S WODSCHOW CO Industrisvinget 6 DK 2605 Broenby www bearvarimixer dk Page Previous page Next page Number of pages Last printed Last corrected Page rev Project rev Appr init date Const project page Drawing no Subject name Project title File name Page title Main Power 1 1 10 06 2011 10 06 2011 VL1 3 ...

Page 10: ...upply Max 16A Customer supplied Fuse 500V 1A Fuse 250V 1 5A Fuse 500V 1A Fuse 250V 1 5A safety micro CE Trafo 0 1 2 3 4 5 6 7 8 9 A S WODSCHOW CO Industrisvinget 6 DK 2605 Broenby www bearvarimixer dk Page Previous page Next page Number of pages Last printed Last corrected Page rev Project rev Appr init date Const project page Drawing no Subject name Project title File name Page title Main Power 1...

Page 11: ...re que le batteur mélangeur ci dessous Verklaart hiermede dat Menger Declaramos que el producto batidora er i overensstemmelse med relevante bestemmelser i Maskindirektivet Direktiv 2006 42 EC is in conformity with the relevant provisions of the Machinery Directive 2006 42 EC konform ist mit den Bestimmungen der EG Maschinenrichtlinie Direktiv 2006 42 EG Satisfait à l ensemble des dispositions per...

Page 12: ...1 09 2017 Försäkrar härmed att denna blandningsmaskin Con la presente si dichiara che questo mixer planetaria Deklareerime käesolevaga et Planetaarmikseri Niniejszym oświadczamy że mikser planetarny vakuuttaa että tämä mikseri tyyppi överensstämmer med tillämpliga bestämmelser i maskindirektivet 2006 42 EG is è conforme alle disposizioni della Direttiva Macchine Direttiva 2006 42 CE vastab kehtiva...

Reviews: