background image

                                           

 

Iron Removal Setup… 

Installation by a certified water treatment professional is highly recommended. 

1.

 

Remove distributor tube and basket from empty tank and remove the wrapping from the basket. 

2.

 

Attach tubing from the air release system (R00018) to the hose barb (R00019) in the in/out head 

(R0005). 

3.

 

Attach the distributor tube into the in/out head. 

4.

 

Secure the air release valve to the distributor tube with a zip tie. 

5.

 

Insert this assembly into the empty tank and screw tight onto the tank. 

6.

 

Screw the filter valve onto the media tank. 

7.

 

Set the filter valve to backwash (regenerate) every five days is typical. (refer to valve manual for 

directions) 

8.

 

Attach connection manifold assembly (R00020) to the in/out head tank. Grease O-rings on each spool to 

prevent damage and leaks. Ensure the orientation of the manifold is in the proper position with the inlet 

to the in/out head first and secure with provided clips. Attach connection manifold assembly to the 

filter valve using provided clips. 

9.

 

Tape and attach the air inlet elbow with check valve (R0008-10) and both sample taps onto the bottom 

of the connection manifold. 

* If sample taps are not desired, please install enclosed plugs. 

10.

 

 Attach plastic bypass to meter assembly/connection manifold with provided clips. 

11.

 

 Connect the length of ¼” tubing to the air pump and elbow with check valve located on the underside 

of the connection manifold. 

12.

 

 Mount air pump bracket in a convenient location, ensuring the cord and tubing reach.   

13.

 

 Plug in F11 filter valve, air pump, and meter monitor to a 120VAC GFI outlet. 

14.

 

 Turn bypass valve on to allow water to flow into the system. 

15.

 

 Manually turn on air pump using the red switch on the back of the pump until air is escaping through 

air release fitting on the top of the in/out head and then turn switch off. The air pump will automatically 

pressurize the tank with future water use. 

 

Summary of Contents for Duraline series

Page 1: ......

Page 2: ...Description of Parts and Application 2 6 Installation Instructions 7 Installation Diagram 8 Part Numbers and Descriptions 9 10 Iron Removal Complete System 11 Contact Information 12 ...

Page 3: ...The In Out Air Release Fitting R00019 comes pre assembled into the In Out Head R0005 Attach the Air Release System R00018 to the hose barb Refer to Installation Instructions 2 page 7 Refer to Figure 2 ...

Page 4: ... pre assembled and fixed to the Connection Manifold R0001 to create the Electronic Manifold Assembly R00020 The Spool Adapter with Check Valve R0006 is installed on the inlet side of the Connection Manifold R0001 with the Monitor Meter R0002 attached ...

Page 5: ... Elbow with Check Valve R0008 10 are included in the kit and will need to be taped and attached to the connection manifold R0001 See Figure 2C If you are not using the sample taps be sure to tape and attach the enclosed plugs instead ...

Page 6: ...ater The Air Pump R00010 connects with tubing that uses a quick release fitting on the pump and is routed to the Elbow with Check Valve R0008 10 Refer to page 4 Figure 2c The Air Pump Bracket R0009 is a stainless steel bracket that provides convenient means to permanently install the pump ...

Page 7: ...be used with quick release fittings and our standard bypass valve 1606P This allows for minimal water usage during the installation of the Iron Kit John Guest fittings are optional Standard Bypass Manifold Assembly with optional John Guest fittings Optional Stainless Steel Bypass Assembly ...

Page 8: ...on with the inlet to the in out head first and secure with provided clips Attach connection manifold assembly to the filter valve using provided clips 9 Tape and attach the air inlet elbow with check valve R0008 10 and both sample taps onto the bottom of the connection manifold If sample taps are not desired please install enclosed plugs 10 Attach plastic bypass to meter assembly connection manifo...

Page 9: ......

Page 10: ...PART DESCRIPTION QTY BYPASS MANIFOLD 1 R0007 SPOOL ADAPTER 2 116018HB 3 4 PLASTIC YOKE 1 R00018 AIR RELEASE SYSTEM PART DESCRIPTION QTY R0008 1 CONNECTOR 1 R0008 8 REDUCER 1 R0008 9 1 4 TUBING 8 INCHES R00011 CHECK VALVE CART 1 R00019 IN OUT AIR RELEASE FITTING PART DESCRIPTION QTY R0008 6 HOSE BARB 1 R0008 7 ELBOW 1 R00020 ELECTRONIC MANIFOLD ASSEMBLY PART DESCRITION QTY R0001 CONNECTION MANIFOLD...

Page 11: ...006 SPOOL CHECK VALVE ASSEMBLY 1 R0008 2 TAP 2 R0008 10 ELBOW with CHECK VALVE 1 R0009 AIR PUMP BRACKET 1 R00010 AIR PUMP 1 R00018 AIR RELEASE SYSTEM 1 R00019 IN OUT AIR RELEASE FITTING 1 R00020 ELECTRONIC MANIFOLD ASSEMBLY 1 SUB ASSEMBLY COMPONENT OPTIONAL COMPONENTS PART DESCRIPTION R0008 4 JOHN GUEST FITTING 1606KB METAL BYPASS 1606K 1 METAL BYPASS ...

Page 12: ...of manganese The air injection process requires careful control of the flow If water usage becomes to great not enough air is applied to oxidize the iron and manganese The advantage of the Hankscraft Iron Removal System is that the aeration is adjustable from immediate on demand to delayed aeration based on real time water usage and the oxidation process can be optimized R00030 IRON REMOVAL SYSTEM...

Page 13: ...Thank you for choosing this Iron Removal system for your water treatment Please contact your service professional with questions Place contact information here ...

Reviews: