Indication
Cause
Measure
Remark
Heating system stays
cold
(2/2)
Pump from heating system is
not functioning.
Check whether the (heating) pump is correctly connected.
If there continues to be insufficient or no hot water,
consult your installation engineer.
Check whether there is power on the (heating) pump
connections on the controller of the Theta dual service module.
The measured voltage must be 230 V
AC
(-15%, +10%)
Check the (hydraulic) operation of the (heating) pump:
1. Bleed the pump, when air is present.
2. Unblock the pump of replace the pump in case of seizing.
Pump from DHW-system is
not functioning.
Check whether the (DHW) pump is correctly connected.
Check whether there is power on the (DHW) pump connections
on the controller of the Theta dual service module. The
measured voltage must be 230 V
AC
(-15%, +10%)
Check the (hydraulic) operation of the (DHW) pump:
1. Bleed the pump, when air is present.
2. Unblock the pump or replace the pump in case of seizing.
3-way mixing valve is not
functioning.
Check whether the 3-way mixing valve is connected (electrical).
Check whether there is power on the (3-way mixing valve)
connections on the controller of the Theta dual service module.
The measured voltage must be 230 V
AC
(-15%, +10%)
Check whether the 3-way mixing valve is correctly (hydraulically)
connected.
Check whether the 3-way mixing valve is correctly configurated
(11.5 "Configuration 3-way mixing valve").
Summary of Contents for Theta T Series
Page 4: ...Theta Dual Service Module 2 0 4...
Page 6: ...Installatie Gebruikers en Service handleiding 6...
Page 16: ...Installatie Gebruikers en Service handleiding 16...
Page 28: ...Installatie Gebruikers en Service handleiding 28...
Page 30: ...Installatie Gebruikers en Service handleiding 30...
Page 32: ...Installatie Gebruikers en Service handleiding 32...
Page 38: ...Installatie Gebruikers en Service handleiding 38...
Page 44: ...Installatie Gebruikers en Service handleiding 44...
Page 46: ...Installatie Gebruikers en Service handleiding 46...
Page 58: ...Installation User and Service Manual 58...
Page 68: ...Installation User and Service Manual 68...
Page 80: ...Installation User and Service Manual 80...
Page 82: ...Installation User and Service Manual 82...
Page 84: ...Installation User and Service Manual 84...
Page 90: ...Installation User and Service Manual 90...
Page 96: ...Installation User and Service Manual 96...
Page 98: ...Installation User and Service Manual 98...
Page 108: ...Installation User and Service Manual 108 11 5 Configuration 3 way mixing valve IMD 1124 R0 0...
Page 109: ...Installation User and Service Manual 109 0311 686 R0 0 NL EN...