Installation, Service and User Manual
34
4.2.2
Work order:
1. Undo bolts from the cover.
2. Remove cover and the gasket.
3. Inspect the tank and remove the loose scale deposits and contamination.
4. If the scale cannot be removed by hand, descale the storage tank with a
descaling agent. Contact the supplier/manufacturer for advice on what descaling
agent to use.
5. Close the cleaning opening. To avoid damage to the tank tighten the bolts, that
fasten the lid, with a torque no greater than 50 Nm. Use suitable tools for this.
Checking anodes
Anodes ensure the protection of the tank by sacrificing themselves. Insufficient anode
material may lead to poor protection and, hence, leakage of the tank.
1. Loosen the anodes one by one.
2. Check the diameter of each anode in different places. The diameter must be at
least 60% of the original
1” diameter.
3. If the diameter is less than the minimum, the anode must be replaced. Please
contact the supplier/manufacturer to order new anodes.
4. Mount the (new) anodes.
Summary of Contents for ST Series
Page 4: ...Installatie Service en Gebruikershandleiding 4 ...
Page 6: ...Installatie Service en Gebruikershandleiding 6 ...
Page 8: ...Installatie Service en Gebruikershandleiding 8 ...
Page 11: ...0312731_ST_400 1000_NLENFR_V3 0 2018 01 04 11 Vooraanzicht doorsnede toestel IMD 1294 R0 ...
Page 12: ...Installatie Service en Gebruikershandleiding 12 ...
Page 22: ...Installation Service and User Manual 22 ...
Page 24: ...Installation Service and User Manual 24 ...
Page 28: ...Installation Service and User Manual 28 ...
Page 38: ...Notice d installation Mode d emploi Notice d entretien 38 ...
Page 40: ...Notice d installation Mode d emploi Notice d entretien 40 ...
Page 43: ...0312731_ST_400 1000_NLENFR_V3 0 2018 01 04 43 Vue de frontale des appareils IMD 1294 R0 ...
Page 44: ...Notice d installation Mode d emploi Notice d entretien 44 ...