Installation-, user and service manual
68
3.5.1
3.5.2
3.5.3
Cold water side
See (A) in the installation diagram (3.5 "Installation diagram").
1. When the mains water pressure exceeds the prescribed pressure (3.3.2 "General
specification"), fit a pressure relieve valve (1).
2. Fit an approved inlet security group (2) under applicable regulation (1.3
"Regulations").
3. Connect the overflow outlet side of the inlet security group (2) via an open connection
to the waste water discharge.
4. Connect a T-piece between the inlet security group (2) and the cold water connection
on the water heater for drainage.
5. Connect a drain valve (the drain valve is not delivered with the water heater).
Caution
An inlet security group is mandatory. Mount the inlet security group as close as possible
to the water heater.
Warning
It is forbidden to connect and stop valve or non return valve between the inlet security
group and the water heater.
Caution
During heating of the water heater (due to temperature increase) water will dribble from
the inlet security group. This is a normal phenomenon. This should never be prevented
of blocked. The outlet of the inlet security group should remain open at all times to its
surroundings.
Hot water side
See (B) in the installation diagram (3.5 "Installation diagram").
1. Mount the top flange (2" connection) incl. the sealant ring by means of bolt/nut-
connection (6x M10).
2. Optional: fit a temperature gauge (12) so you can check the temperature of the tap
water.
3. Connect the overflow side of the T&P (3) via an open connection to the waste water
discharge.
4. Fit a stop valve (11) in the hot water outlet pipe for servicing.
5. When a circulation pipe is needed, continue with the mounting of the circulation pipe
(3.6.3 "Circulation pipe").
Note
Insulating long hot water pipes prevent unnecessary energy loss.
Circulation pipe
See (C) in the installation diagram (3.5 "Installation diagram").
If an immediate flow of hot water is required at draw-off points, a circulation pump can be
installed. This improves comfort, and reduces water wastage.
1. Fit a circulation pump (6) of the correct capacity for the length and resistance of the
circulation system.
2. Fit a non-return valve (5) after the circulation pump to guarantee the direction of
circulation.
3. Fit two stop valves for servicing (4).
4. Connect the circulation pipe according to the installation diagram (3.5 "Installation
diagram").
Summary of Contents for ITES 1000
Page 2: ......
Page 4: ......
Page 5: ......
Page 6: ......
Page 8: ...Installatie gebruikers en servicehandleiding 6...
Page 14: ...Installatie gebruikers en servicehandleiding 12...
Page 16: ...Installatie gebruikers en servicehandleiding 14...
Page 28: ...Installatie gebruikers en servicehandleiding 26...
Page 30: ...Installatie gebruikers en servicehandleiding 28...
Page 34: ...Installatie gebruikers en servicehandleiding 32...
Page 36: ...Installatie gebruikers en servicehandleiding 34...
Page 40: ...Installatie gebruikers en servicehandleiding 38...
Page 42: ...Installatie gebruikers en servicehandleiding 40...
Page 54: ...Installation user and service manual 52...
Page 56: ...Installation user and service manual 54...
Page 62: ...Installation user and service manual 60...
Page 64: ...Installation user and service manual 62...
Page 76: ...Installation user and service manual 74...
Page 78: ...Installation user and service manual 76...
Page 82: ...Installation user and service manual 80...
Page 84: ...Installation user and service manual 82...
Page 88: ...Installation user and service manual 86...