Make sure that there is no grit or other blockages in the drain pipe (3).
Make sure that the slope of the drain pipe is correct; 5 mm/m.
Install the condense trap onto the condensate drain.
Fig. Condensate drain
1
2
3
1. Condensate drain
2. Condense trap
3. Drain pipe
11.4
Gas-side maintenance
Do gas side maintenance when the water heater does not operate correctly, the air
pressure differential is not correct and/or the CO
2
value is not correct.
To do gas side maintenance:
Clean the burner (see section 11.4.1)
Clean the combustion chamber (see section 11.4.2)
11.4.1
Clean the burner
Remove the burner engine:
Close the gas control valve, refer to Installation diagram (see section 8.3).
Disconnect all plugs from the burner engine (1).
Disconnect the gas supply pipe (2).
Loosen the two bolts (3) to disconnect the burner engine (4) from the adapter.
Take the burner engine out of the water heater.
Fig. Remove the burner engine
2
1
4
3
1. Plugs on burner
engine
2. Gas supply pipe
3. Bolts
4. Burner engine
6.
7.
8.
•
•
1.
2.
3.
4.
5.
0312266_INNOVO_UKUK_V3.0, 2017-02-10
65
Summary of Contents for Innovo 12-160
Page 6: ...6...
Page 13: ...User part 0312266_INNOVO_UKUK_V3 0 2017 02 10 13...
Page 14: ...14...
Page 16: ...16 User part...
Page 18: ...18 User part...
Page 24: ...24 User part...
Page 27: ...Installation Maintenance and Service part 0312266_INNOVO_UKUK_V3 0 2017 02 10 27...
Page 28: ...28 User part...
Page 36: ...36 Installation Maintenance and Service part...
Page 43: ...Fig Venting systems 0312266_INNOVO_UKUK_V3 0 2017 02 10 43...
Page 58: ...58 Installation Maintenance and Service part...
Page 70: ...70 Installation Maintenance and Service part...
Page 83: ...0312266_INNOVO_UKUK_V3 0 2017 02 10 83...
Page 87: ...13 5 Declaration of conformity 0312266_INNOVO_UKUK_V3 0 2017 02 10 87...