background image

9

Figure 13

Connect one end  of the d ischarg e tub e to 

the Multi-function Safety valve and  

connect the other end  to the d rain.

To Drain

Blue Cap

Multi-function
Safety Valve

Discharg e Tub e

Note:

 The Multi-function Safety valve m ay d rip  d uring  the usag e of the heater. As the w ater  

 

is heated , it exp and s and  tries to flow b ack throug h the inlet p ip e b ut is p revented  b y  

 

the p resence of the non-return valve. Hence w ater m ay d rip  from  the Multi-function  

 

Safety valve. Therefore a Discharg e tub e is g iven from  the valve tip  to a nearb y d rain.  

 

To avoid  d rip p ing , it is recom m end ed  to install non-return valve at a d istance of  

 

 

atleast 40 feet aw ay from  the inlet of the w ater heater.

‡ 7KH0XOWLIXQFWLRQ6DIHW\YDOYHVKRXOGQHYHUEHUHPRYHGRUEORFNHGE\DQ\PHDQVWR

 

 

p revent it from  d rip p ing  or releasing  the excess p ressure insid e the heater. Failure to d o  

 

 

 

so m ay result in d am ag e to the w ater heater and  injuries to the user. This w ill also  

 

 

 

m ake the w arranty null and  void .

‡ 'LVFKDUJHWXEHVKRXOGEHLQVWDOOHGGRZQZDUGVZLWKRXWDQ\ORRSVIROGVRUNQRWV

 

 

Ensure that the free end  of the Discharg e tub e is p laced  over a suitab le d rain and  aw ay  

 

 

 

from  the users. 

‡ 'LVFKDUJHWXEHLVSURYLGHGWRUHOHDVHWKHGLVFKDUJHIURPWKHZDWHUKHDWHUWKURXJKWKH

 

 

Multi-function Safety valve) in case excessive p ressure is d evelop ed . The contents of the  

 

 

 

d ischarg e from  the Multi-function Safety valve m ay b e hot and  m ay cause b urns to the  

 

 

 

users and  d am ag e nearb y ob jects if not p rop erly routed  to a d rain.

‡ ,WLVUHFRPPHQGHGWRRSHUDWHWKH'LVFKDUJHOHYHULQWKH0XOWLIXQFWLRQ6DIHW\YDOYHRQ

 

 

a reg ular b asis to ensure that there are no b lockag es and  also to rem ove any lim e   

 

 

 

d ep osits that w ould  have b een form ed  insid e the w ater heater.

‡ (QVXUHWKDWWKHZDWHUKHDWHULVLQSRZHU2))FRQGLWLRQZKHQWKH'LVFKDUJH/HYHULV

 

 

b eing  op erated . Ensure that the w ater is filled  com p letely in the w ater heater b efore  

 

 

 

sw itching  it ON.

‡ (QVXUHWKDWWKHLQVXODWLRQRI0XOWLIXQFWLRQ6DIHW\YDOYHLVQRWGDPJHGZKLOHWLJKWHQLQJ

CAUTION

Summary of Contents for HSE-VAS015

Page 1: ...onday to Friday 9 am to 8 pm Saturday Sunday 9 am to 6 pm For calls registered at A O Smith call centre before 4 pm only Available only in selected cities For more details please call our 1800 103 246...

Page 2: ...known as A O Smith India Water Heating Private Limited Plot 300 Phase II KIADB Industrial Area Harohalli Kanakapura T aluk Ramanagara District Karnataka 562 112 India CIN U31909KA2006PTC040282 A O Smi...

Page 3: ...lve 8 Connecting to Water Supply 10 Operation 11 Temperature Conrol Knob 12 Troubleshooting 14 Circuit Diagram 15 Warranty 16 Jurisdiction 17 Expert Company Service 17 Service and Maintenance 19 Conte...

Page 4: ...a shipment has been delivered to you in apparent good condition but upon opening the packaging if any loss or damage has taken place while in transit inform the carrier s agent A O Smith representati...

Page 5: ...tion instructions 1 Inspect the water heater and its component parts for possible damage Do Not install or attempt to repair any damaged component parts If you detect any damage in the water heater pl...

Page 6: ...m set temperature 75 C may vary 5 C Model Vertical Wall Mounted HSE VAS 015 HSE VAS 025 HSE VAS 035 HSE VAS 050 Volume L 15 25 35 50 Power W 2000 Voltage Frequency V Hz 230 50 Actual Stdg Loss 0 450 0...

Page 7: ...ator lamp 4 Heating indicator lamp 5 Anode 6 Cold water inlet pipe with diffuser 7 Hot water outlet pipe 8 Blue Cap 9 Red Cap 10 Thermal Cut out 11 Thermostat 12 Heating Element 13 Wall Mount Bracket...

Page 8: ...ng is stronger and more corrosion resistant than any other in the industry Multi function Safety Valve The Multi function safety valve is designed to automatically relieve pressure and discharge water...

Page 9: ...es on the water heater Figure 4 Safety Precautions Installation Before installing ensure that the following tools are available Figure 5 Tools Required CAUTION CAUTION Bubble Level Indicator Measuring...

Page 10: ...ure 8 8VH D GULOO ELW ZLWK GLDPHWHU RI PP WR drill 2 holes at least 90mm deep in the wall Fig 8 Step 3 The two holes should be aligned horizontally The horizontal distance between the 2 holes should b...

Page 11: ...y valve to cold water inlet pipe and rotate it in clockwise direction till it get fixed Water Heater Concrete Wall 1 Water Heater Wall 2 Wall Water Heater 3 Wall mount bracket Hanging Screw WARNING Ho...

Page 12: ...er and injuries to the user This will also make the warranty null and void LVFKDUJH WXEH VKRXOG EH LQVWDOOHG GRZQZDUGV ZLWKRXW DQ ORRSV IROGV RU NQRWV Ensure that the free end of the Discharge tube is...

Page 13: ...WHU SLSH WR WKH RXWOHW Red Cap WWDFK WKH GLVFKDUJH WXEH WR Multi function Safety valve as shown in Installation Diagram Fig 14 Connecting to Water Supply Figure 14 Installation Diagram Hot Water T ap...

Page 14: ...unting Multi function Safety valve Plumbing and Water filling is completed then only the power supply should be switched ON Figure 15 Connecting to Electrical Supply Figure 16 The power cord and plug...

Page 15: ...l Figure 18 Heating mode Standby mode When the actual temperature of the water is less than the set temperature it enters into Heating mode The Heating indicator lamp glows as shown in Fig 18 After th...

Page 16: ...nit and drain it Switch OFFthe electric supplyto the water heater Open the hot water faucet untilthe water runs cool Close cold water supply Drain the water bylifting the Discharge Lever of the Multi...

Page 17: ...alibration Call Customer care centre Thermal Cut out trips Call Customer care centre Water heats slowly Heating Element is not Call Customer care centre functioning Piping connection leaks Connection...

Page 18: ...15 Circuit Diagram Figure 21 Element Red L PE N Red Brown Green Black Thermostat Green Yellow Black Tank Body Thermal Cutout Green light Red light...

Page 19: ...any repair or part replacement in the water heater the basic warranty continues as per the actual date of purchase 8 The customer will have no claim under this warranty in respect of any personal inj...

Page 20: ...actual basis i e by paying the Labour Cost and Spares needed to attend to that Service or Complaint Call at the prevailing Company rates Such service will be rendered by the Company in towns or places...

Page 21: ..._________ Ph _______________ Mobile _____________________ E mail ___________________ Warranty Card Company Copy to be sent back to the Company Dealer s Stamp and Signature Invoice Number _____________...

Page 22: ...ustrial Area Harohalli Kanakapura T aluk Ramanagara District Karnataka 562 112 India Customer Care No 1800 103 2468 1860 500 2468 Website www aosmithindia com CIN U31909KA2006PTC040282 For Service nee...

Page 23: ......

Page 24: ...vate Limited formerly known as A O Smith India Water Heating Private Limited Plot 300 Phase II KIADB Industrial Area Harohalli Kanakapura T aluk Ramanagara District Karnataka 562 112 India Customer Ca...

Reviews: