background image

1.  Open a hot water faucet nearby to permit the air to escape.

2.  Open the cold water inlet valve fully, filling the heater and the piping. 

3.  Close the hot water faucet when water flows.

4.  Check all the connections to see if there is any leakage. In case of a leakage, drain the 

heater completely, repair the leaking joint and then refill the heater.

 Electrical Connections

The power cord and plug are connected with this water heater. Find a separate socket for 
power plug and make sure the socket is in firm contact with the plug. Ensure that reliable 
earthing has been done.

4

Caution: 

 

•  Connect the water heater using independent sockets, do not use adapters. Use 

multimeter to check whether the live line and neutral line are not reverse, to ensure 
complete safety. 

 

•  Before installing the water heater, confirm that the power of water heater matches 

electric meter capacity and supply wire.

 

•   The water heater should be earthed reliably. It is prohibited to connect the earth wire 

to neutral wire or tap water pipe.

Attention: 

 

•  Make sure a suitable sealing tape is used for all connections to prevent leakage.

 

•  Discharge tube should be installed downwards without any loops, folds or knots. 

Ensure that the free end of the Discharge tube is placed over a suitable drain and away 
from the users.

 

•  Discharge tube is provided to release the discharge from the water heater(through the 

safety valve) in case excessive pressure is developed. The contents of the discharge 
from the Safety valve may be hot and may cause burns to the users and damage 
nearby objects if not properly routed to a drain.

 

•  It is recommended to operate the discharge lever in the safety valve on a regular basis 

to ensure that there are no blockages and also to remove any lime deposits that would 
have been formed inside the water heater. 

 

•  Ensure that the water heater is in power OFF condition when the Discharge lever is 

being operated. Ensure that the water is filled completely in the water heater before 
switching it ON.

Water Filling

 Plumbing

1.  Make necessary plumbing with reference to the installation diagram. (Fig. 5)

2.  A. O. Smith recommends nylon/SS braided hoses having  a minimum pressure rating of 

8 Bar and hoses should be compatible for hot water applications.

3.  Connect the cold water pipe to the inlet [Blue Cap]. 

4.  Connect the hot water pipe to the outlet [Red Cap]. 

5.  Attach the discharge tube to safety valve as shown in installation diagram. (Fig. 5 & 6)

Summary of Contents for HSE-SBS-015

Page 1: ...you have a water heater that works in Indian water conditions Guaranteed A O Smith Service within 24 hours Call 1 800 103 2468 Made in India s most modern and advanced water heater factory ADVANCED T...

Page 2: ......

Page 3: ...rom any phone anywhere in the country to our Toll Free Customer Care No 1 800 103 2468 Or Factory Address A O Smith India Water Heating Private Limited Plot No 300 Phase 2 KIADB Industrial Area Haroha...

Page 4: ...ter heater Conditio ns Apply User Guide Water Heater HSE SBS 015 HSE SBS 025 Blue Diamond glass lined tank Maximum protectio n against hard water and corrosion Get the best quality that ensures you ha...

Page 5: ...et connections Inch Dimensions 1 Caution Safety valve has been factory fit with the water heater and set at 0 8 MPa 8 Bar rated pressure Warning Do not tamper or detach the safety valve from the water...

Page 6: ...nology increases the life of the inner tank The lining is stronger and more corrosion resistant than any other in the industry The safety valve is designed to automatically relieve and discharge water...

Page 7: ...vertical distance should be 57mm Fig 2 4 Insert the expansion anchors into the holes Place the wall mounting bracket over the expansion anchors and tighten the screws on the bracket Fig 3 5 Place the...

Page 8: ...ube should be installed downwards without any loops folds or knots Ensure that the free end of the Discharge tube is placed over a suitable drain and away from the users Discharge tube is provided to...

Page 9: ...scharge Tube Safety Valve Port Installation of wired remote controller Fig 7 Installation of Bracket for wired remote controller Fig 8 Bracket for wired remote controller 24mm Wall For convenience of...

Page 10: ...is connected it is in initial power on state i e the heater is ready for heating the water The wired remote controller will perform the diagnosis function and all indicators will glow and goes off as...

Page 11: ...s than the set temperature it enters into Heating mode The indicator glows as shown in Fig 14 b Standby mode After the water heater reaches set temperature it will enter into the Standby mode due the...

Page 12: ...ss and remove the cap Unscrew Remove the Decorative Front Panel to change Fig 16 Removing decorative front panel Attention The product of your choice comes with either white or ivory as a front panel...

Page 13: ...ternal wiring error Piping connection Connection not sealed Re connect piping using tape leaks thread sealant Refer plumbing instructions on page 4 Water leakage Leakage in tank or Shut off power imme...

Page 14: ...Circuit Diagram Black Black Blue Thermal Cutout Power Board Element Green Yellow Red Red Red Wired Remote 10...

Page 15: ...the defects repairs alterations required or carried out or certifying working of the goods thereafter 4 The Company or its Authorised service provider will be entitled to retain any defective part re...

Page 16: ...ce Contract he has the option of calling our Authorised service provider and having his A O Smith Water Heater unit serviced on actual basis i e by paying the Labour Cost and Spares needed to attend t...

Page 17: ...Stamp and Signature Invoice Number Dated Customer s Name and Address Model Capacity Warranty Card Warranty Card Customer Copy To be retained by the Customer Unit Serial Number Dealer s Stamp and Signa...

Page 18: ...ea Harohalli Kanakapura Taluk Ramanagara District 562 112 Karnataka India Toll Free No 1 800 103 2468 Website www aosmithindia com 14 Regional Office Delhi 105 106 Plot No 19 Sagar Plaza Laxmi Nagar D...

Page 19: ......

Page 20: ...ndia Water Heating Private Limited Plot No 300 Phase 2 KIADB Industrial Area Harohalli Kanakapura Taluk Ramanagara District 562 112 Karnataka India Toll Free 1 800 103 2468 Website www aosmithindia co...