Only professional installers acknowledged by A.O.SMITH are permitted to install the heat pump 

water heater. Ifthe water heater is installed with self-prepared installation materials or by 

un-authorized personnel, A.O.SMITH will not be responsible for all losses incurred thereby, 

including but not limited to pipeline leakage, fall or improper installation that may affect normal 

operation and performance of water heater.

The heat pump water heater is for residential application. Therefore, it may affect life expectation 

if it is used for commercial application.

After installation and operation of the heat pump water heater, users should inspect the system regu-

larly and make necessary maintenance according to operation conditions. If any abnormality 

occurs, please stop operation immediately, and contact local authorized dealer for repair to ensure 

the normal, safe, and reliable operation of the water heater.

The anode rod is a consumable part and it is generally suggested to check and replace the anode rod 

every 2 or 3 years. Users could contact the local authorized dealer for check and replacement to 

extend life expectation of water heater.

Prior to any maintenance or repair of the heat pump water heater, please cut off power supply. 

Unauthorized personnel are not permitted to adjust and repair the heater.

In case of any component soaked by water, the water heater is not permitted to use until checked by 

authorized service staff.

Main components of the heat pump water heater are protected by insulation material to ensure 

safety use. Any damaged power cords should be replaced by authorized service staff.

The pressure relief valve, equipped on the heat pump water heater, is forbidden to change installa-

tion position or be blocked. Discharge pipe is required to connect the valve and down toward floor 

drain.

In case of any fault in ground wire circuit, tri-polar power-off protection system will cut off all 

connection between water heater and electric supply circuit instantaneously. Please stop using, pull 

the plug, and contact local authorized dealer

.

Water, including hot water, out of the heat pump water heater is not permitted for drinking.

Electricity for the heat pump water heater should be supplied by independent branch of circuit, of 

which electricity meter, breaker, maximum current need to be checked by professional 

electrician in advance.

Power socket should be located at a dry place, and power cord should not be pushed or pulled with wet hand 

to avoid the danger of electric shock. 

   

Summary of Contents for HPW-60AT

Page 1: ...Heat Pump Water Heater HPW 60 80AT User Guide HPW 60 80AE...

Page 2: ...as gained respect and support of homeowners contractors architects and specifying engineers in over 60 countries by providing innovative energy saving products designed for years of trouble free servi...

Page 3: ...ulation Installation Instructions 5 Mounting 5 Mounting Procedures and Precautions Mounting Consolidation 7 Pipe Connection 8 Three pass Discharge Pipe Connection 8 Condensate Water Pipe Connection 8...

Page 4: ...of water heater Prior to any maintenance or repair of the heat pump water heater please cut off power supply Unauthorized personnel are not permitted to adjust and repair the heater In case of any com...

Page 5: ...Caution Failure to follow instructions in the user guide may cause fire disaster which would be a threat to life and property security Warning Heat pump water heater is not permitted for use without...

Page 6: ...Outlet pipe hot Inlet pipe cold Relief valve Condensate pipe Rated Heating Output Fig 1 Appearance Features Model Specifications Physical Characteristics Mpa g dB A kg HPW 60AT AE HPW 80AT AE 0 8 0 8...

Page 7: ...stantaneously and simultaneously to guarantee safety in case water temp reach the high temp limited due to water heater fault If this happens please contact local authorized dealer Safety Valve A safe...

Page 8: ...i rust and anti scaling glass coating has pass 100 000 cycles fatigue life test in accordance with relevant UL Standards A powerful steel core anode rod is used to protect tank and greatly prolong ser...

Page 9: ...eater Vertical installation of the water heater is strictly prohibited Make sure to use original accessories to install the heater Do not mount the heater until accessories are fixed on wall or it may...

Page 10: ...s not over tightened Match up two sets of hooks and holes of hanging panels to the back of the heater and then move the heater down to get fixed Fig 5 Proper Improper Notice Original installation acce...

Page 11: ...cket are fitting Connect a safety valve to the inlet tube i e blue cap side of heater keeping arrow accord with water flow i e toward the heater Refer to Fig 7 for more detail Connect a discharge pipe...

Page 12: ...Q ORVH 5 9 DWWHU 6L H 5RWDWH DIWHU SUHVVLQJ 2SHQ FORVH E D FRLQ 2SHQ ORVH 5 9 DWWHU 6L H 5RWDWH DIWHU SUHVVLQJ 2SHQ FORVH E D FRLQ Fig 8 z 8VLQJ LPSDFW HOHFWULF GULOO ZLWK PP GULOO PDNH WZR KRUL RQWDO...

Page 13: ...st for a few minutes and then power off Notice When water heater is disconnected with power supply by plug out or power cut the tempera ture timer 1 timer 2 AES and MAX will load status before the bre...

Page 14: ...and hold button for a few seconds will enter clock setting status With hour digit flashing user could press or to set hour digit within the range form 0 to 23 With minute digit flashing user could pr...

Page 15: ...urbo mode the heater is heating both efficiently and rapidly Notice z When choose Efficiency mode heater will not work until 3 minutes after power on Fig 16 Fig 17 WithTimer 1 indicator light up user...

Page 16: ...pup and power indicator turned from green into orange Please try to push reset button if it does not work contact local authorized dealer Notice User should check the tri polar power off protection sy...

Page 17: ...flush the tank until clean water come out of tank 5 Connect water inlet and outlet pipes referring to Fig 7 and check if there is leakage Warning Ensure heater is disconnected from power source before...

Page 18: ...orized dealer Display E6 Red wiring with two core terminal short circuit or open circuit Contact local authorized dealer Display E7 Blue wiring with two core terminal short circuit or open circuit Con...

Page 19: ...XH KLWH Compressor ODFN DSDFLWRU Compressor protector 7UDQVIRUPHU DQ 0RWRU URZQ OXH OXH 5HG HDWHU L Input Below Yellow L Input Compressor Yellow L Input N Output N Input LVSOD HOORZ HDWHU 7HPSHUDWXUH...

Page 20: ...and wiring match up with each other The heat pump water heater should be grounded reliably It is prohibited to connect the earth wire to neutral wire or tap water pipe Water of 50 or above may have r...

Page 21: ...A O SMITH WATER HEATER CO LTD A O Smith reserves the right to make product changes or improvements at any time without notice 500444 010 Rev 02...

Reviews: