7
L
L(mm)
HPW-60AT/AE
260
380
HPW-80AT/AE
Fig.4 Distance between Appearance Features
Notice:
Before insert screw into punching, a nylon expansion tube wire should get through
the hole of hook first.
Use an inner hexangular spanner to screw in, and other tooling are suitable.
.
Ensure the counter sunk head of the screw is not over-tightened Match up two sets
of hooks and holes of hanging panels to the back of the heater, and then move the
heater down to get fixed.
.
Fig.5
Proper
Improper
Notice:
Original installation accessories should be used on solid wall. The heater may
have has risk of fall in case of improper installation. Refer to Fig.5.
Mounting Consolidation
Consolidation is essential when install the heater on nonbearing wall. Refer to Fig.6.
Fig.6 Mounting Consolidation
Fix hanging panels on the wall
Model
Non bearing wall