background image

2

z

 

Damaged electric wire, aged, loose and unfixed socket are not suggested to be used because of the 

danger of electric shock, short circuits, fires, etc. Please ensure power cord and socket could be 

connected well. 

A. O. SMITH (China) water Heater Company Ltd reserves the rights to explain all provisions men-

tioned above. 

Caution:

 Failure to follow instructions in the user guide may cause fire disaster, which would 

                   be a threat to life and property security.

Warning:

 

 

 

 

Heat pump water heater is not permitted for use without reliable ground wire 

 circuit for power socket. In case of indicator lighted up for “ground wire circuit 

fault”, please immediately stop using, pull plug and contact local authorized 

dealer. Well-drained floor drain is essential to prevent the damage to surround-

ings or downstairs in case of leakage of heater or joint.

Summary of Contents for HPW-60AE

Page 1: ...Heat Pump Water Heater HPW 60 80AT User Guide HPW 60 80AE ...

Page 2: ...has gained respect and support of homeowners contractors architects and specifying engineers in over 60 countries by providing innovative energy saving products designed for years of trouble free service A O Smith Water Products Company now the largest water heater manufacturer in the world continues the tradition of innovation and becomes a global leader in water product industry ...

Page 3: ...sulation Installation Instructions 5 Mounting 5 Mounting Procedures and Precautions Mounting Consolidation 7 Pipe Connection 8 Three pass Discharge Pipe Connection 8 Condensate Water Pipe Connection 8 Power Connection 8 Water Filling 9 Remote Controller Operation Instructions Electronic Controller Operation Electric Leakage Inspection 10 Safety Valve Inspection 13 Remote Controller Maintenance Ins...

Page 4: ... of water heater Prior to any maintenance or repair of the heat pump water heater please cut off power supply Unauthorized personnel are not permitted to adjust and repair the heater In case of any component soaked by water the water heater is not permitted to use until checked by authorized service staff Main components of the heat pump water heater are protected by insulation material to ensure ...

Page 5: ...e Caution Failure to follow instructions in the user guide may cause fire disaster which would be a threat to life and property security Warning Heat pump water heater is not permitted for use without reliable ground wire circuit for power socket In case of indicator lighted up for ground wire circuit fault please immediately stop using pull plug and contact local authorized dealer Well drained fl...

Page 6: ...4 Outlet pipe hot Inlet pipe cold Relief valve Condensate pipe Rated Heating Output Fig 1 Appearance Features Model Specifications Physical Characteristics Mpa g dB A kg HPW 60AT AE HPW 80AT AE 0 8 0 8 35 75 35 75 10 44 10 44 10 55 10 55 R134a R134a 123 123 40 40 42 45 Table 3 Specifications Model Water Temp Range Rated Tank Pressure Ambient Temp Range in Efficienc Mode Water Temp Range in Efficie...

Page 7: ...nstantaneously and simultaneously to guarantee safety in case water temp reach the high temp limited due to water heater fault If this happens please contact local authorized dealer Safety Valve A safety valve shown in fig 1 Model G1 2 0 8 default 0 8MPa not adjustable by user is equipped on inlet tube of heat pump water heater The valve will relieve pressure automatically when piping system press...

Page 8: ...ti rust and anti scaling glass coating has pass 100 000 cycles fatigue life test in accordance with relevant UL Standards A powerful steel core anode rod is used to protect tank and greatly prolong service life of the heat pump water heater Hot water over 50 has the risk of causing scald Please do take care of your family when settingtemp over 50 2 or more staffs are needed to move or install the ...

Page 9: ...heater Vertical installation of the water heater is strictly prohibited Make sure to use original accessories to install the heater Do not mount the heater until accessories are fixed on wall or it may fall down and cause accident Independent branch of circuit with diameter of wire no less than 2 5mm is suggested as max input power of the heater is 2 5kW Ensure mounting wall can afford at least fo...

Page 10: ...is not over tightened Match up two sets of hooks and holes of hanging panels to the back of the heater and then move the heater down to get fixed Fig 5 Proper Improper Notice Original installation accessories should be used on solid wall The heater may have has risk of fall in case of improper installation Refer to Fig 5 Mounting Consolidation Consolidation is essential when install the heater on ...

Page 11: ...ocket are fitting Connect a safety valve to the inlet tube i e blue cap side of heater keeping arrow accord with water flow i e toward the heater Refer to Fig 7 for more detail Connect a discharge pipe with safety valve Connect the hot water pipe to the outlet tube i e red cap side For safety valve installation please refer to chapter of Safety Feature If water pressure of inlet pipe approaches or...

Page 12: ...Q ORVH 5 9 DWWHU 6L H 5RWDWH DIWHU SUHVVLQJ 2SHQ FORVH E D FRLQ 2SHQ ORVH 5 9 DWWHU 6L H 5RWDWH DIWHU SUHVVLQJ 2SHQ FORVH E D FRLQ Fig 8 z 8VLQJ LPSDFW HOHFWULF GULOO ZLWK ĭ PP GULOO PDNH WZR KRUL RQWDO SXQFKLQJ EHWZHHQ ZKLFK WKH distance should be 28mm Refers to Fig 8 Use expansion pipes and screws in accessories to fix bracket on the wall Ensure that the heater and socket are both reliably groun...

Page 13: ...ast for a few minutes and then power off Notice When water heater is disconnected with power supply by plug out or power cut the tempera ture timer 1 timer 2 AES and MAX will load status before the break By power on more than 4 hours the heater could keep clock setting information for 72 hours when power supply is cut off Press Power ON OFF button the heater will be power on Setting temp and actua...

Page 14: ...g and hold button for a few seconds will enter clock setting status With hour digit flashing user could press or to set hour digit within the range form 0 to 23 With minute digit flashing user could press or to set minute digit within the range form 0 to 59 User could change the status among hour digit minute digit and exit by touching With Timer 1 indicator light up user could press and hold butt...

Page 15: ...Turbo mode the heater is heating both efficiently and rapidly Notice z When choose Efficiency mode heater will not work until 3 minutes after power on Fig 16 Fig 17 WithTimer 1 indicator light up user could press and hold button to enterTimer 1 setting status and set in the same way of Timer 1 With heater power on choose mode of Efficiency or Hybrid Turbo by touch Mode button Fig 16 17 z If rapid ...

Page 16: ...opup and power indicator turned from green into orange Please try to push reset button if it does not work contact local authorized dealer Notice User should check the tri polar power off protection system regularly as follow With power indicator initially in green press Test button to turn it off and press reset button to turn it back to green Otherwise contact local authorized dealer The functio...

Page 17: ... flush the tank until clean water come out of tank 5 Connect water inlet and outlet pipes referring to Fig 7 and check if there is leakage Warning Ensure heater is disconnected from power source before maintenance to avoid electric shock Notice User may do some easy repair works referring to the trouble shooting chart before contact local authorized dealer Declaration Notice Be cautious about the ...

Page 18: ...horized dealer Display E6 Red wiring with two core terminal short circuit or open circuit Contact local authorized dealer Display E7 Blue wiring with two core terminal short circuit or open circuit Contact local authorized dealer Display H6 Green wiring with six core terminal short circuit or open circuit Contact local authorized dealer Display H7 Blue wiring with six core terminal short circuit o...

Page 19: ...OXH KLWH Compressor ODFN DSDFLWRU Compressor protector 7UDQVIRUPHU DQ 0RWRU URZQ OXH OXH 5HG HDWHU L Input Below Yellow L Input Compressor Yellow L Input N Output N Input LVSOD HOORZ HDWHU 7HPSHUDWXUH SURWHFWLRQ VZLWFK RQQHFWRU 7KHUPR 6HQVRU 7KHUPR 6HQVRU OXH ...

Page 20: ...r and wiring match up with each other The heat pump water heater should be grounded reliably It is prohibited to connect the earth wire to neutral wire or tap water pipe Water of 50 or above may have risk of scald Please check water temp by hand and use water mixing valve to get water in appropriate temperature Be cautious about the hot water discharge through safety valve as it may have risk to c...

Page 21: ...A O SMITH WATER HEATER CO LTD A O Smith reserves the right to make product changes or improvements at any time without notice 500444 010 Rev 02 ...

Reviews: