background image

18

2.2.4 Temperature 

Regulation

The device is continuously under 
water pipe pressure (maximum 8 bar 
(=800 kPa)). Cold water may be fed 
if hot water is being consumed. The 
regulating thermostat switches the feed 
automatically. That means that if the 
thermostat measures a temperature 
lower than the set temperature, then it 
closes the electrical circuit so that an 
electrical current is conducted through 
the heating element. As soon as the 
desired temperature is reached the 
thermostat breaks the contact once 
again. When there are high water 
temperatures, scaling in the device 
occurs. Therefore it is recommended 
to allow the temperature setting to stay 
at 60°C so that less scale is formed. 
A maximum thermostat is installed 
above each regulating thermostat 
which shuts off the current feed to the 
element permanently (locking) at a 
water temperature of 93°C. In order to 
put the element back into operation the 
reset button of the maximum thermostat 
must be pressed in. If the temperature 
climbs above 98°C the temperature and 
pressure valve 

fi

 tted open for safety 

reasons.

2.3 Maintenance

The boiler must be tested and cleaned 
by a recognised installation engineer 
at least once per year so that good 
operation can be guaranteed. During 
maintenance the device must never be 
under voltage.

2.3.1 Sacri

fi

 cial anode

The life of the anodes is determined 
by the quality and the quantity of water 

fl

 owing through the device. It is thus 

recommended that the anodes are 
checked every year.
1.  Close the stop valve in the cold 

water feed pipe.

2.  Open up the nearest hot-water tap 

so that the water pressure in the 
boiler and pipeline drops.

3.  Loosen the anode using a correct 

spanner.

4.  Check the anode and replace if this 

is tarnished above 60%.

5.  Replace the anode in a water-tight 

way.

If it is necessary to replace the anode, 
it must be replaced with one of the 
same type. The type of anode can be 
established via the device type and the 
complete serial number.

2.3.2 Descaling

Scaling depends on the water condition 
and the water demand. Besides, more 
scale deposit will be formed in the device 
at high temperatures than at lower 
temperatures. A temperature setting of 60 
ºC is recommended to ensure low scale 
deposit. Descale using the appropriate 
agents. A descaling instruction is available 
for detailed information.

2.4 

Steps When There is a 

Fault

Warning: 

Always ensure that the device is 
completely free of voltage before the 
door is opened!

Summary of Contents for DURA-Power DRE-52

Page 1: ...HOT WATER STORAGE DEVICES england MODELS DRE 52 DRE 80 DRE 120 INSTALLATION AND USER INSTRUCTIOINS...

Page 2: ...this manual and in conformity with the General Terms and Conditions as filed with the Chamber of Commerce For further information see the General Terms and Conditions These can be obtained from us fr...

Page 3: ...t of Operation 17 2 2 4 Temperature Regulation 18 2 3 Maintenance 18 2 3 1 Sacrificial anode 18 2 3 2 Descaling 18 2 4 Steps When There is a Fault 18 2 4 1 Water Temperature Not Good 19 2 4 2 Presumed...

Page 4: ...el plate which has a glass lined coating on the inside The tank is also provided with two sacrificial anodes to give extra protection against corrosion A thick CFC free polyurethane insulation layer c...

Page 5: ...5 Fig 1 regulation and safety 1 2 Regulation and Safety For clarification see the diagram below the image is an extract from the electrical diagram further on...

Page 6: ...to the regulating thermostat 9 The element 10 is fed from the regulating thermostat During normal operation the regulating thermostat 9 switches the element 10 on and off If a temperature of above 93...

Page 7: ...e exposure height is too small the contact will no longer connect even if the float is completely above it In this case the device will not come into operation If the exposure height is set lower than...

Page 8: ...and 1 5 Ohms Screw the float switch back into the tank and place it vertically Check the exposure height Close the door and connect the feed voltage The safety relays must not come in The tautening a...

Page 9: ...meter of boiler 560 640 750 E Depth 690 790 910 M Height of drain valve 125 125 125 R Height cold water supply 125 125 125 S Height T P connection 1230 1335 1380 1 Cold water connection 1 14NPT 1 14NP...

Page 10: ...uous 40 C litres hour 241 258 482 516 963 1032 Weight kg 73 73 73 Type DRE 80 9 DRE 80 18 DRE 80 36 DRE 80 54 Tank capacity litres 300 300 300 300 Number of elements 3 3 6 9 Power 380V 3F kW 7 6 15 2...

Page 11: ...ing time up to 40 400 414V min 112 105 56 52 28 26 19 17 Tap capacity 1st hour 60 C 400 414V litres 569 579 707 726 981 1020 1256 1314 Tap capacity continuous 60 C 400 414V litres hour 145 155 289 310...

Page 12: ...itted in such a way that it constantly slopes upwards A stop valve or non return valve must never be fitted between the inlet combination and the device During heating of the device expansion water as...

Page 13: ...elow Diagram A Diagram B Diagram C Electrical diagram for 3 phase Electrical diagram for 3 phase Electrical diagram for 3 phase connection connection with 3 elements connection with 6 elements with ni...

Page 14: ...connection B Fuses C Relay D Fuse E Transformer F Safety relay G Float switch H Maximum thermostat K Regulation thermostat L Electrical heating element X1 Terminal block 1 Black Zwart Schartz Noir 2...

Page 15: ...nsformer F Safety relay G Float switch H Maximum thermostat K Regulation thermostat L Electrical heating element X1 Terminal block 1 Black Zwart Schartz Noir 2 Red Rood Rot Rouge 3 Blue Blauw Blau Ble...

Page 16: ...connection B Fuses C Relay D Fuse E Transformer F Safety relay G Float switch H Maximum thermostat K Regulation thermostat L Electrical heating element X1 Terminal block 1 Black Zwart Schartz Noir 2...

Page 17: ...et the desired temperature on the regulating thermostat see table When leaving the factory the temperature is set at 60 C Temperature in F Temperature in C 120 49 130 54 140 60 150 66 160 71 170 77 18...

Page 18: ...d cleaned by a recognised installation engineer at least once per year so that good operation can be guaranteed During maintenance the device must never be under voltage 2 3 1 Sacrificial anode The li...

Page 19: ...ximum thermostats which break the circuit when the water temperature is too high 93 C These maximum thermostats can only be reset again once the temperature has dropped 20 C Then the regulating thermo...

Page 20: ...se Solution Insufficient or no hot water Temperature set too low Set regulating thermostats higher Maximum thermostats break the circuit Press in reset button Connector is not seated in stop contact m...

Page 21: ...1 Check whether the device is filled with water 2 Switch the mains switch on for a fixed connection or place the connector in the stop contact 3 1 3 Use The device is under water pipe pressure maximu...

Page 22: ...t hot water drainage point for ventilating the tank Take care that the feed pipe and inlet combination cannot freeze Drain the feed pipe as necessary and check whether all other pipes are empty 3 2 Ma...

Page 23: ...ccording to the installation instructions of A O Smith for the specific model as well as according to the local and national installation and building regulations instructions and rules b that the boi...

Page 24: ...or any parts thereof ex the Veldhoven warehouse Any costs involved with transport labour installation or any other capacity connected to the replacement cannot be charged to A O Smith 4 6 Claims A cl...

Page 25: ...25...

Page 26: ...26 0310 145_R1...