3.  FOR THE USER

3.1 

Instructions for Use

Warnings

The installation and commissioning shall 
be done by a recognised installer.

Always make the device free of 
voltage before opening the door. Have 
maintenance and fault recti

fi

 cation 

carried out by authorised personnel. 
Never work on the device while feed 
voltage is still present.

The device may not be operated by 
people (including children) with limited 
psychological and/or mental abilities, 
lack of experience and knowledge 
unless they have received agreement 
or instruction from a person who is held 
responsible for their safety.

From the point of view of safety it must 
be ensured that children do not play with 
the device.

3.1.1  Filling the Device

Method of working:
1.  Check whether the drain valve is 

closed.

2.  Open cold water valve to the boiler and 

open all valves at hot water drainage 
points for bleeding. The device is 

fi

 lled 

as soon as cold water 

fl

 ows at all 

drainage points.

3.  Reclose all valves at hot water drainage 

points.

3.1.2  Putting into operation

Method of working:
1.  Check whether the device is 

fi

 lled 

with water.

2.  Switch the mains switch on for 

fi

 xed connection or place the 

connector in the stop contact.

3.1.3 Use

The device is under water pipe pressure 
(maximum 8 bar (=800 kPa)). As 
much cold water is fed is as hot water 
consumed. The regulating thermostat 
switches the electrical feed automatically. 
This means that if the temperature 
rises above the desired temperature, 
the circuit is closed and heat is fed to 
the water. The circuit is broken once 
again when the desired temperature is 
reached.

Changing the set temperature is an 
operation which must be carried out by a 
recognised installer. For this purpose the 
device must be made completely voltage 
free before the access door to the 
regulating thermostats may be opened.

Temperature in °F

Temperature in °C

120

49

130

54

140

60

150

66

160

71

170

77

180

82

In connection with limiting scaling it is 
recommended to set the temperature 
at 60°C. A maximum thermostat is also 
installed which interrupts the circuit fully 
at a water temperature of 93°C. This 
thermostat can be reset again once the 
temperature of the water has dropped 
by 20°C. If the maximum thermostat 
intervenes again the regulating 
thermostat must be set to a lower 
temperature.

Summary of Contents for DURA-Power DRE-52

Page 1: ...HOT WATER STORAGE DEVICES england MODELS DRE 52 DRE 80 DRE 120 INSTALLATION AND USER INSTRUCTIOINS...

Page 2: ...this manual and in conformity with the General Terms and Conditions as filed with the Chamber of Commerce For further information see the General Terms and Conditions These can be obtained from us fr...

Page 3: ...t of Operation 17 2 2 4 Temperature Regulation 18 2 3 Maintenance 18 2 3 1 Sacrificial anode 18 2 3 2 Descaling 18 2 4 Steps When There is a Fault 18 2 4 1 Water Temperature Not Good 19 2 4 2 Presumed...

Page 4: ...el plate which has a glass lined coating on the inside The tank is also provided with two sacrificial anodes to give extra protection against corrosion A thick CFC free polyurethane insulation layer c...

Page 5: ...5 Fig 1 regulation and safety 1 2 Regulation and Safety For clarification see the diagram below the image is an extract from the electrical diagram further on...

Page 6: ...to the regulating thermostat 9 The element 10 is fed from the regulating thermostat During normal operation the regulating thermostat 9 switches the element 10 on and off If a temperature of above 93...

Page 7: ...e exposure height is too small the contact will no longer connect even if the float is completely above it In this case the device will not come into operation If the exposure height is set lower than...

Page 8: ...and 1 5 Ohms Screw the float switch back into the tank and place it vertically Check the exposure height Close the door and connect the feed voltage The safety relays must not come in The tautening a...

Page 9: ...meter of boiler 560 640 750 E Depth 690 790 910 M Height of drain valve 125 125 125 R Height cold water supply 125 125 125 S Height T P connection 1230 1335 1380 1 Cold water connection 1 14NPT 1 14NP...

Page 10: ...uous 40 C litres hour 241 258 482 516 963 1032 Weight kg 73 73 73 Type DRE 80 9 DRE 80 18 DRE 80 36 DRE 80 54 Tank capacity litres 300 300 300 300 Number of elements 3 3 6 9 Power 380V 3F kW 7 6 15 2...

Page 11: ...ing time up to 40 400 414V min 112 105 56 52 28 26 19 17 Tap capacity 1st hour 60 C 400 414V litres 569 579 707 726 981 1020 1256 1314 Tap capacity continuous 60 C 400 414V litres hour 145 155 289 310...

Page 12: ...itted in such a way that it constantly slopes upwards A stop valve or non return valve must never be fitted between the inlet combination and the device During heating of the device expansion water as...

Page 13: ...elow Diagram A Diagram B Diagram C Electrical diagram for 3 phase Electrical diagram for 3 phase Electrical diagram for 3 phase connection connection with 3 elements connection with 6 elements with ni...

Page 14: ...connection B Fuses C Relay D Fuse E Transformer F Safety relay G Float switch H Maximum thermostat K Regulation thermostat L Electrical heating element X1 Terminal block 1 Black Zwart Schartz Noir 2...

Page 15: ...nsformer F Safety relay G Float switch H Maximum thermostat K Regulation thermostat L Electrical heating element X1 Terminal block 1 Black Zwart Schartz Noir 2 Red Rood Rot Rouge 3 Blue Blauw Blau Ble...

Page 16: ...connection B Fuses C Relay D Fuse E Transformer F Safety relay G Float switch H Maximum thermostat K Regulation thermostat L Electrical heating element X1 Terminal block 1 Black Zwart Schartz Noir 2...

Page 17: ...et the desired temperature on the regulating thermostat see table When leaving the factory the temperature is set at 60 C Temperature in F Temperature in C 120 49 130 54 140 60 150 66 160 71 170 77 18...

Page 18: ...d cleaned by a recognised installation engineer at least once per year so that good operation can be guaranteed During maintenance the device must never be under voltage 2 3 1 Sacrificial anode The li...

Page 19: ...ximum thermostats which break the circuit when the water temperature is too high 93 C These maximum thermostats can only be reset again once the temperature has dropped 20 C Then the regulating thermo...

Page 20: ...se Solution Insufficient or no hot water Temperature set too low Set regulating thermostats higher Maximum thermostats break the circuit Press in reset button Connector is not seated in stop contact m...

Page 21: ...1 Check whether the device is filled with water 2 Switch the mains switch on for a fixed connection or place the connector in the stop contact 3 1 3 Use The device is under water pipe pressure maximu...

Page 22: ...t hot water drainage point for ventilating the tank Take care that the feed pipe and inlet combination cannot freeze Drain the feed pipe as necessary and check whether all other pipes are empty 3 2 Ma...

Page 23: ...ccording to the installation instructions of A O Smith for the specific model as well as according to the local and national installation and building regulations instructions and rules b that the boi...

Page 24: ...or any parts thereof ex the Veldhoven warehouse Any costs involved with transport labour installation or any other capacity connected to the replacement cannot be charged to A O Smith 4 6 Claims A cl...

Page 25: ...25...

Page 26: ...26 0310 145_R1...

Reviews: