DISPENSER PRECAUTIONS
1. Water can only be dispensed continually for a maximum of 10 minutes.
2. Operating two buttons at the same time will stop the flow of water. To resume, return both buttons to their
original position and try again.
3. When water has just begun to boil in the tank or when water temperature is high, air bubbles may enter the
hot water pump, resulting in poor water flow. Please allow a few seconds for the water to settle and try
again.
4. When boiling has only just begun or if system has been inactive for a long period of time, the first glass of
dispensed water may not be as hot.
5. In the process of boiling, the cover of the tank and the body of the heater may feel warm to touch. This is
normal.
6. If the system is newly installed or has not been used for a long time, users are recommended to drain the hot
water twice before consumption.
FAUCET PRECAUTIONS
1. After 10 minutes of inactivity, the system enters sleep mode and the panel will only display the logo and child
lock indicator. Touch any key on the panel to exit sleep mode.
2. If the heat function of the system is deactivated, sleep mode will only display the logo, child lock indicator
and the filter life indicator.
THE WATER TANK
Power button
Heating should begin the instant the system is powered on. Press and hold the power button for 3
seconds to power the system on or off. You should hear a beep each time the button is activated.
Precautions
1. To prevent freezing in an extremely cold environment, the system will automatically power on should the
water temperature fall below 5ºC.
2. If the system has been powered on and is maintaining a fixed temperature for over 3 days with no usage, the
heat function will go off. Pressing any key on the system will reactivate it.
FAULT CODES
Code
Possible reason
Code
Possible reason
F8
Dry heating
E1
Water temperature
sensor fault
C4
Overheating
E6
Steam temperature
sensor fault
C2
Level sensor data
incorrect
C1
Level sensor failure