10-10. Thermistors
Unit Part #
#422 (Inlet)
#433 (Output)
#418 (Mixing)
AOS Part #
319143-085 (Inlet)
319143-096 (Output)
319143-081 (Mixing)
Checkpoint
E1 (Mixing)
E2 (Output)
E3 (Inlet)
Function
Measure cold / hot water temperatures in the water heater.
Failure event
Unable to properly measure water temperatures within the water heater.
Effects on the water
heater if thermistor
fails
If the thermistors fail open or short, error code appears before starting operation.
If resistance values are just off, water heater will have temperature fluctuations in
hot water.
Error codes when
thermistors fails
311 (Output)
321 (Inlet)
331 (Mixing)
Diagnostic
1. Visual inspection: connection / breakage of wires and/or debris on thermistor.
2. Check voltages and resistance; proper range of values shown below.
Inlet Black (42)-Black
Output Black (12)-Black
Color / Number of
wires
Mixing Black (113)-Black
68˚F (20°C)
9.0 to 13 kΩ
122˚F (50°C)
3.3 to 4.4 kΩ
176˚F (50°C) 1.4 to 1.8 kΩ
(see table below for more resistance values)
Resistance values of thermistors as a function of temperature
0.00
5.00
10.00
15.00
20.00
25.00
20
40
60
80
100
120
140
160
180
200
220
Temperature / ºF
R
es
is
ita
nc
e
/ k
Ω
(Inlet thermistor) 42
(
Mixing
thermistor)
113
(
Output
thermistor)
12
Blue
Black
Black
Insulating