Boiler Installation and Owners Manual
5
LDJ991_E01_R03_2006.03
Models LDJ991 and LDJ991-10
I
N S T A L L A T I O N
A N D
L
O C A T I O N
C
O N S I D E R A T I O N S
Failure to install the A-MAIZE-ING HEAT
®
boiler according to the
guidelines and instructions contained within this manual may result in
serious injury or death, property damage, or voiding of the warranty.
Boiler Clearances and Accessibility
The following are the minimum distances the
boiler may be to a combustable surface:
top ......................................................................... 32"
either side ............................................................... 6"
front ....................................................................... 30"
back cabinet surface ............................................... 6"
flue connector on back .......................................... 18"
For ease of service, the following minimum
distances are recommended:
top ......................................................................... 32"
side opposite bin ................................................... 24"
front....................................................................... 36"
rear-most surface on back (boiler or flue) ............. 18"
The overall dimensions of the A-MAIZE-ING
HEAT
®
boiler are as follows:
boiler cabinet width ............................................... 22"
boiler cabinet depth (with door)............................. 36"
boiler cabinet height.............................................. 59"
storage bin width................................................... 35"
storage bin depth .................................................. 51"
storage bin height ................................................. 47"
overall width when assembled
(as configured above) ........................................... 67"
12"
18" (**)
36" (*)
24" (*)
22"
35"
51"
*Minimum service distance
**Minimum combustable clearance