background image

UF SERIES watER FIltRatIon SyStEm

2

A.J. Antunes & Co.

P/N 1010808 Rev. E 03/12

General

VIZION of A.J. Antunes & Co., has partnered with 

companies from around the globe to produce the UF 

Series water filtration systems. The UF Series removes 

bacteria and provides a substantial reduction of viruses 

that can enter a typical water supply. This patented 

technology is now available to you, sized for your par-

ticular application.  All filter configurations utilize NeoH 

capillary membranes, providing the latest innovation in 

reusable surface filtration technology.

This manual provides the safety, installation and  

operating procedures for the UF-Series water filtration 

systems. We recommend that all information contained 

in this manual be read prior to installing and operating 

the unit. 

Your UF-Series unit is manufactured from the finest 

materials available and is assembled to our strict  

quality standards. This unit has been tested at the  

factory to ensure dependable trouble-free operation. 

Owner InfOrmatIOn

table Of cOntents

ImpOrtant!  Keep these instructions for future reference.  If the unit changes  

ownership, be sure this manual accompanies the equipment.

warranty Information

Please read the full text of the Limited Warranty in this 

manual.

If the unit arrives damaged, contact the carrier imme-

diately and file a damage claim with them.  Save all 

packing materials when filing a claim.  Freight damage 

claims are the responsibility of the purchaser and are 

not covered under warranty.
The warranty does NOT extend to:

  •  Damages caused in shipment or damage as 

result of improper use.

  •  Installation of electrical service.

  •  Normal maintenance as outlined in this manual.

  •  Malfunction resulting from improper maintenance.

  •  Damage from moisture leaking into electrical 

 

components.

  •  Normal maintenance as outlined in this manual.

  •  Damage from tampering with, removal of, or 

changing any preset control or safety device.

Owner Information .....................................................2

General ......................................................................2

Warranty Information .................................................2

Important safety Information ....................................3

Service/Technical Assistance ....................................3

Electrical Cord & Plug Configurations .......................5

specifications .............................................................5

Electrical Ratings .......................................................5

Dimensions

 ................................................................5

Specifications (Filter Cartridges) ...............................5

specifications .............................................................6

Installation ...................................................................7

Unpacking ..................................................................7

Equipment Setup .......................................................7

Locating and Mounting the system

 ...........................8

Filtration Process .....................................................11

LED Display

 .............................................................11

Operation ...................................................................11

Starting the System .................................................11

Programming Timer During Startup

 .........................12

Setting the Flush Interval (FI) ..................................12

Setting Flush Duration (FD)

 .....................................12

Checking the Timer Program ...................................14

Changing the Cartridges .........................................14

maintenance ..............................................................14

Manual Flushing

 ......................................................14

troubleshooting .......................................................15

replacement parts Uf-216/224 ...............................16

wiring Diagram .........................................................18

notes..........................................................................19

lImIteD warrantY ...............................back cover

Summary of Contents for UF-224 Series

Page 1: ...Water filtration system UF 216 224 Series Owner s Manual P N 1010808 Rev E 03 12 Manufacturing Numbers 9700430 9700432 9700433...

Page 2: ...the Limited Warranty in this manual If the unit arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims...

Page 3: ...ent For your safety the equipment is furnished with a properly grounded cord connector Do NOT attempt to defeat the grounded connector Install or locate the equipment only for its intend ed use as des...

Page 4: ...re to follow these instructions could result in serious injury or death Electrical ground is required on this unit Do NOT modify the power supply cord plug If it does not fit the outlet have a proper...

Page 5: ...ou are unsure if the appliance is properly grounded Specifications Filter Cartridges Maximum Operating Pressure 7 bar 100 psi Maximum Operating Temp 40 C 104 F Trans Membrane Pressure 0 5 2 5 Bar 7 36...

Page 6: ...IES water Filtration system 6 A J Antunes Co P N 1010808 Rev E 03 12 Specifications Components LED Display Program Button Power Cord Filter Cartridge Figure 1 System Components Strainer Permeate Drain...

Page 7: ...member to use a back up wrench on the supporting plumbing Always use a good quality approved pipe sealant or thread seal tape on pipe threads Be careful not to get the pipe sealant inside the pipe whe...

Page 8: ...ion to the inlet of the filter system hold a bucket or other con tainer at the inlet water line and slowly open the inlet water valved Allow the pipe to flush until all debris is removed Permeate Line...

Page 9: ...ing in minutes or hours The F8 and Fi sequence repeats for 30 seconds after which the unit automatically returns to the Flush Interval Mode Fi The time setting for Fi will be displayed and the decimal...

Page 10: ...downstream to the filter system 3 Close the inlet water valve and allow the system to depressurize 4 Place a bucket under the strainer at the inlet connection to the system Open the strainer by unscr...

Page 11: ...sh Duration Fd on LED display During the Flush Interval mode water enters the inlet and flows through the filter element before exiting the Permeate outlet as usable product water After a certain peri...

Page 12: ...ally returns to Flush Interval Mode NOTE Fi times are displayed in ten minute inter vals after fifty minutes they are displayed in hours Table A Figure 7 LED Display for Flush Duration Mode Figure 8 T...

Page 13: ...inter vals after fifty minutes they are displayed in hours Table B TO SET FD FLUSH DURATION MODE 1 Press and hold down start button for four seconds Release button LED will display Fd 2 When Fd is di...

Page 14: ...ed for long life eventually the cartridges will need to be replaced 1 Open the faucet or tap closest downstream to the filtration system 2 Close the inlet water valve and allow the system to depressur...

Page 15: ...growth in pipes Sanitize plumbing Water conditions changed Consider installing taste and odor filtration Broken capillary in Filter Cartridge Replace Filter Cartridge Flush runs continuously Drain Va...

Page 16: ...NC 1 2 NPT For Mfg 9700432 10 7000357 Solenoid Valve Coil Kit 120 V 1 For Mfg 9700430 7000358 Solenoid Valve Coil Kit 230V 1 For Mfg 9700432 13 0503981 Clamp Filter 2 1 14 0503984 Mounting Bracket 2 1...

Page 17: ...ES water filtration system 17 A J Antunes Co P N 1010808 Rev E 03 12 Replacement parts UF 216 224 continued 14 6 13 5 26 1 2 15 17 17 25 23 20 21 22 28 3 4 18 16 16 18 7 8 24 10 9 19 29 29 32 34 30 31...

Page 18: ...es Co P N 1010808 Rev E 03 12 Wiring Diagram TIMER BOARD SOLENOID VALVE RED BLK T2 T3 T4 WHT BLK GND TERMINAL BLOCK GRN YEL WHT BLU BLK BRN POWER CORD NOTE ALL WIRED TO BE 16 GA AWM 105 C UNLESS OTHER...

Page 19: ...UF SERIES water filtration system 19 A J Antunes Co P N 1010808 Rev E 03 12 Notes...

Page 20: ...operating and main tenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 A J Antunes Co reserves the right to make changes in design or...

Reviews: