background image

UF SERIES watER FIltRatIon SyStEm

13

A.J. Antunes & Co.

P/N 1010808 Rev. E 03/12

OperatIOn (continued)

Programming continued

programming timer while Unit is in flush 

Interval (fI) mode

tO set fI - flUsH InterVal mODe

nOte:  after power-up and cycling - fi time setting  

displays a flashing decimal point.

  1.  Press and hold down 

start

 button for four  

seconds. Release button, LED will display 

Fd

  

followed by its setting. 

  2.  When 

Fi

 (Figure 9) is displayed, press and release 

button to view current setting.

  3.  To make a change, press and hold down the 

start

 

button to scroll through settings - release button at 

desired setting (Figure 10).

  4.  After ten seconds, if 

start

 button is not pressed, 

unit automatically returns to Flush Interval Mode.

nOte: fi times are displayed in ten minute inter-

vals, after fifty minutes they are displayed in hours 

(table b).

tO set fD - flUsH DUratIOn mODe

  1.  Press and hold down 

start

 button for four  

    seconds. Release button, LED will display 

Fd

.

  2.   When 

Fd

 is displayed (Figure 11), press and  

release button to view current setting.

  3.  To make a change, press and hold down 

start

 

button to scroll through settings - release button 

at desired setting (Figure 12).

  4.  After ten seconds, if 

start

 button is not pressed 

unit automatically returns to Flush Interval Mode.

nOte: fd times are displayed in 5 second intervals 

up to 60 seconds (table b).

figure 11. leD Display for flush Duration

figure 12. time Display for fd mode (15 seconds)

table b.  leD Display settings

figure 10. time display for fi mode (30 minutes)

figure 9. fi - leD Display for flush Interval mode

 

1-

 

10 minutes 

 

 5

 

 5 seconds

 

5-

 

50 Minutes 

 

10

 

10 seconds

 

01

   1 Hour   

 

15

 

15 Seconds

 

12

 

12 Hours 

 

30

 

30 Seconds

 

24

  24 hours 

 

60

  

60 Seconds

Fi - Flush Interval Mode

Fd - Flush Duration Mode

Summary of Contents for UF-224 Series

Page 1: ...Water filtration system UF 216 224 Series Owner s Manual P N 1010808 Rev E 03 12 Manufacturing Numbers 9700430 9700432 9700433...

Page 2: ...the Limited Warranty in this manual If the unit arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims...

Page 3: ...ent For your safety the equipment is furnished with a properly grounded cord connector Do NOT attempt to defeat the grounded connector Install or locate the equipment only for its intend ed use as des...

Page 4: ...re to follow these instructions could result in serious injury or death Electrical ground is required on this unit Do NOT modify the power supply cord plug If it does not fit the outlet have a proper...

Page 5: ...ou are unsure if the appliance is properly grounded Specifications Filter Cartridges Maximum Operating Pressure 7 bar 100 psi Maximum Operating Temp 40 C 104 F Trans Membrane Pressure 0 5 2 5 Bar 7 36...

Page 6: ...IES water Filtration system 6 A J Antunes Co P N 1010808 Rev E 03 12 Specifications Components LED Display Program Button Power Cord Filter Cartridge Figure 1 System Components Strainer Permeate Drain...

Page 7: ...member to use a back up wrench on the supporting plumbing Always use a good quality approved pipe sealant or thread seal tape on pipe threads Be careful not to get the pipe sealant inside the pipe whe...

Page 8: ...ion to the inlet of the filter system hold a bucket or other con tainer at the inlet water line and slowly open the inlet water valved Allow the pipe to flush until all debris is removed Permeate Line...

Page 9: ...ing in minutes or hours The F8 and Fi sequence repeats for 30 seconds after which the unit automatically returns to the Flush Interval Mode Fi The time setting for Fi will be displayed and the decimal...

Page 10: ...downstream to the filter system 3 Close the inlet water valve and allow the system to depressurize 4 Place a bucket under the strainer at the inlet connection to the system Open the strainer by unscr...

Page 11: ...sh Duration Fd on LED display During the Flush Interval mode water enters the inlet and flows through the filter element before exiting the Permeate outlet as usable product water After a certain peri...

Page 12: ...ally returns to Flush Interval Mode NOTE Fi times are displayed in ten minute inter vals after fifty minutes they are displayed in hours Table A Figure 7 LED Display for Flush Duration Mode Figure 8 T...

Page 13: ...inter vals after fifty minutes they are displayed in hours Table B TO SET FD FLUSH DURATION MODE 1 Press and hold down start button for four seconds Release button LED will display Fd 2 When Fd is di...

Page 14: ...ed for long life eventually the cartridges will need to be replaced 1 Open the faucet or tap closest downstream to the filtration system 2 Close the inlet water valve and allow the system to depressur...

Page 15: ...growth in pipes Sanitize plumbing Water conditions changed Consider installing taste and odor filtration Broken capillary in Filter Cartridge Replace Filter Cartridge Flush runs continuously Drain Va...

Page 16: ...NC 1 2 NPT For Mfg 9700432 10 7000357 Solenoid Valve Coil Kit 120 V 1 For Mfg 9700430 7000358 Solenoid Valve Coil Kit 230V 1 For Mfg 9700432 13 0503981 Clamp Filter 2 1 14 0503984 Mounting Bracket 2 1...

Page 17: ...ES water filtration system 17 A J Antunes Co P N 1010808 Rev E 03 12 Replacement parts UF 216 224 continued 14 6 13 5 26 1 2 15 17 17 25 23 20 21 22 28 3 4 18 16 16 18 7 8 24 10 9 19 29 29 32 34 30 31...

Page 18: ...es Co P N 1010808 Rev E 03 12 Wiring Diagram TIMER BOARD SOLENOID VALVE RED BLK T2 T3 T4 WHT BLK GND TERMINAL BLOCK GRN YEL WHT BLU BLK BRN POWER CORD NOTE ALL WIRED TO BE 16 GA AWM 105 C UNLESS OTHER...

Page 19: ...UF SERIES water filtration system 19 A J Antunes Co P N 1010808 Rev E 03 12 Notes...

Page 20: ...operating and main tenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 A J Antunes Co reserves the right to make changes in design or...

Reviews: