background image

MUFFIN TOASTER MT-12

14

P/N 1010610 Rev. Q 07/16 

McDonald’s

TROUBLESHOOTING (continued)

Problem

Possible Cause

Corrective Action

Toaster fails to operate (no 

heat, fan not running).

No power.

Make sure plug is locked into position 

and the power is on.  Check building 

circuit breaker.

Defective receptacle or power cord plug. Plug into different receptacle. 

Replace cord.

Loose wire connections.

Check and tighten all connections.

Not heating. Fan is working.

Hi-Limit thermostat is tripped or  

defective.

Turn toaster off for 20-30 minutes and 

then press the reset button. 

Replace Hi-Limit thermostat.

Removable Plate is scuffed or scratched. Replace Removable Plate.
Removable Plate is too dull has excess 

carbon build-up.

Clean or replace Removable Plate.

Muffins too light or too dark at 

Audio Signal.

Using refrigerated or frozen muffins.

Muffins must be at room temperature 

before toasting.  Allow a two day old 

rotation when using fresh muffins.

Incorrect setting or regional preference 

dictates an adjustments of the timer.  

Approximate times are: 

Partial Load - 85-125 seconds 

Full Load - 90-130 seconds

NOTE: If your toasting times differ 
from the values above, contact the 
factory for assistance.

Adjust full or partial load timers as 

needed.  

Toaster does not operate 

properly when it is initially 

installed.

Toaster selected/shipped is not for the 

electrical service as this location.

Check toaster identification plate and 

refer to the Electrical Specifications of 

this Manual.

Toaster does not operate 

after the replacement of a 

Control Board.

One or more electrical service dip 

switches are improperly set for the loca-

tions electrical service.

Refer to the Dip Switch setting instruc-

tions provided in this manual.

Toaster will not operate (no 

heat and no fan operation) 

LED light on and Rocker 

Switch not lit.

Unit not turned on.

Confirm that the power is on.

No Power.  Circuit Breaker is off or 

tripped.

Reset Circuit Breaker.  Contact your 

maintenance person or Authorized 

Service Agency if it trips again.

Rocker Switch is inoperable.

Replace Rocker Switch.

Poor plug to receptacle connection.

Lock plug into receptacle.

Damaged or defective power cord.

Inspect power cord, replace if needed.

Damaged or defected cord, plug, and/or 

pins.

Inspect plug and pins.  Replace if 

needed.

Damaged or defective receptacle.

Inspect receptacle. Call your electrician.

Loose electrical connection.

Contact your maintenance person or 

Authorized Service Agency for service.

Summary of Contents for MT-12

Page 1: ...100 miles 160 km 2 hours round trip Antunes Food Service reserves the right to make changes in design or add improvements on any products The right is always reserved to modify Equipment because of f...

Page 2: ...operator with an audible beep and a ready light when muffins are ready The toaster is capable of producing up to 324 muffins per hour 6 muffin halves or less is a partial load and 7 12 muffin halves i...

Page 3: ...or repair Do NOT block or cover any openings on the unit Do NOT immerse cord or plug in water Keep cord away from heated surfaces Do NOT allow cord to hang over edge of table or counter Do NOT clean...

Page 4: ...oduct design without notice Such revisions do NOT entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment IMPORTANT Keep these instructions...

Page 5: ...00 17 0 50 60 L6 30P 30 Amp 250 Volt MT 12 9200136 200 240 3400 17 0 50 60 HBL Pin Sleeve 30 Amp 250 Volt MT 12 9200137 230 3400 14 8 50 60 IEC 309 230 Volt Non Molded Plug MT 12 9200138 220 240 3400...

Page 6: ...ASTER MT 12 6 P N 1010610 Rev Q 07 16 McDonald s Dimensions SPECIFICATIONS continued 4 7 16 112 7 mm 26 5 8 650 8 mm 26 5 8 650 8 mm 13 5 8 346 mm 15 5 8 398 8 mm 14 3 4 374 6 mm 8 1 8 206 4 mm 7 1 8...

Page 7: ...rvice pay attention to the following guidelines Make sure the power is off and the unit is at room temperature before plugging in the power cord Do NOT block or cover any openings on the unit Do NOT i...

Page 8: ...door Next slide the loaded Spatula into the unit 4 NOTE If the self test fails a series of beeps will sound see Diagnostic Flow Chart in Troubleshooting NOTE When the Amber light is on a Partial Load...

Page 9: ...G TIMES Full Load 90 130 seconds Partial Load 85 125 seconds 5 6 OPERATION continued NOTE The indicator lights blinks and the Audio Signal beeps when the toast cycle completes Partial Load READY Remov...

Page 10: ...lines Stains and spots should be removed using a vinegar solution Finger marks and smears should be rubbed off using soap and water CAUTION If a chemical cleaner is used be sure it is safe to use on...

Page 11: ...pwatch when the Audio Signal beeps NOTE The Audio Signal should beep and the Ready light should come on within 90 to 130 seconds 5 Open the front door to stop the Audio Signal and to turn off the Read...

Page 12: ...0216 B 1 YELLOW RED 1 2 PARTIAL DS1 LED DONE SW PARTIAL BUZZER ON SSR THERM FAULT SW FULL PARTIAL FULL 200 HIGH B D A C LOW 220 DS1 C35 C31 J3 J2 C7 C22 C4 C12 C8 C18 C2 C1 C6 C5 C27 C15 C19 C11 C23...

Page 13: ...times waits 2 seconds and continues until unit is turned off More than 750 F 400 C control turns solid state relay off Audio Signal beeps 3 times waits 2 seconds beeps 3 times waits 2 seconds and cont...

Page 14: ...differ from the values above contact the factory for assistance Adjust full or partial load timers as needed Toaster does not operate properly when it is initially installed Toaster selected shipped...

Page 15: ...re is no Audio Signal replace the Audio Signal No Ready Light but Audio Signal works Defective Ready Light If Ready Light Diagnostic LED is on but the Ready Light is not replace the Ready Light No Aud...

Page 16: ...MT 12CU 1 Mfg No 9200144 Japan L6 20P 20A 250V Straight Twist Lock 0700699 Power Cord Assy MT 12HM 1 Mfg No 9210150 Harmonized Marechal Pn Sleeve 220 250 VACT 32 Amp New Zealand 0700442 Power Cord As...

Page 17: ...ASTER MT 12 17 P N 1010610 Rev Q 07 16 McDonald s Partial Load 1 3 5 6 7 8 9 10 11 12 13 14 15 28 28 30 31 32 33 56 40 40 46 46 H 50 50 50 50 50 50 52 53 View A Next Page 57 37 7 5 REPLACEMENT PARTS c...

Page 18: ...CEMENT PARTS continued 1 2 3 4 5 7 16 17 18 22 23 24 25 26 27 34 35 36 20 38 39 40 40 41 42 43 44 45 46 46 48 49 50 57 50 50 50 50 50 51 52 54 19 55 View A NOTE Refer to the Replacement Parts list in...

Page 19: ...1 4 2 3 NAT GND 16 GA AWM 105 C GRN YEL BLK WHT 16 GA SF2 200 C NAT 4 1 2 5 WHT WHT BLK BLK BOARD CONTROL LOAD PARTIAL LIGHT READY WHT BLK FAN HIGH LIMIT HEATER TERMINAL SWITCH BLOCK POWER IND LIGHT 5...

Page 20: ...MUFFIN TOASTER MT 12 20 P N 1010610 Rev Q 07 16 McDonald s NOTES...

Reviews: