RAPID TOASTER VCT-200
19
P/N 1010710 Rev. N 02/13
McDonald’s
TROUBLESHOOTING (continued)
Problem
Possible Cause
Corrective Action
Buns Sticking
Compression Settings incorrect.
Set the Bun Thickness Compression Controls to
“D & 5” for 17 second toasters. For 10 second
toasters, set the controls to “B & 3” (see Figures
2A & 2B).
Improper cleaning of the Release
Sheet and or Groovy Belt Wrap.
Follow the cleaning and/or replacement instruc-
tions on the current MRC Card and immediately
clean the “APSC” off with a clean, dry towel
dampened with sanitizer solution.
Roller Tensionor out of position.
Adjust or replace Roller Tensioner according to
the Maintenance section of this manual.
Note:
Replace a damaged Roller Tensioner.
Product is over-toasterd or
Platen heat is too high or
drop time is too slow.
Temperature set too high
Reset Platen temperature to 560°F (293°C).
Bun Adjustment Controls set
incorrectly.
Set Bun Adjustment Controls correctly. Refer to
the Operation section of this manual.
Groovy Belt Wraps worn and not
permitting belt to pull buns across
Platen in required time.
Clean or replace Groovy Belt Wrap.
Groovy Belt not Tacky.
Buns Sticking on Release Sheet. Clean or replace Release Sheet.
Groovy Belts installed incorrectly. Re-install Groovy Belts according to the
Maintenance section of this manual.
Defective Drive Chain or loose
sprocket.
Contact your mantenance person or Authorized
Service Agency.
Defective Drive Motor or wrong
RPM Drive Motor.
Defective Temperature Display
Control.
Product is under toasted
or Platen heat is too low or
drop time is too fast.
Temperature set too low.
Reset Platen temperature to 560°F (293°C).
Compression Settings incorrect.
Set the Bun Thickness Compression Controls to
“D & 5” for 17 second toasters. For 10 second
toasters, set the controls to “B & 3” (see Figures
2A & 2B).
Groovy Belt Wrap slipping or
streched.
Clean and adjust Conveyor Belt/Chain. Refer to
the Maintenance section of this manual.
Platen Thermocouple is defec-
tive.
Contact your maintenance person or Authorized
Service Agency.
Defective Control Board.
Unit makes high-pitched
squeal or whining noise.
Drive motor.
If noise is identified as coming from the motor,
replace the motor.
Bearings.
Replace bearings.
Ball Bearings.
Replace Ball Bearings.