IMPORTANT SAFETY INSTRUCTIONS
12
Operate outdoors in a well-ventilated,
well-lit area isolated from working
areas to avoid noise interference.
Operate outdoors in a well-ventilated,
well-lit area isolated from working
areas to avoid noise interference.
Operating the generator in wet
conditions could result in
electrocution. Keep the unit dry.
Keep the generator a minimum of 3
feet away from all types of
combustible material.
Do not operate generator near
hazardous material.
Do not operate generator at a gas or
natural gas filling station.
Do not touch the muffler or cylinder
during or immediately after use; they
are HOT and will cause burn injury.
This generator has a neutral floating
condition. This means the neutral
conductor is not electrically
connected to the frame of the
machine.
Do not allow the generator’s gas tank
to overflow when filling. Fill to 1 in.
below the top neck of the gasoline
tank to allow for fuel expansion. Do
not cover the fuel tank cap when the
engine is running. Covering the fuel
tank cap during use may cause
engine failure and/or damage to the
tool.
Place the generator on a flat, stable
surface with a slope of no more than
4°.
Do not use this generator to provide
power for emergency medical
equipment or life support devices.
Exhaust contains poisonous carbon
monoxide, a colorless, odorless gas.
Breathing exhaust can cause loss of
consciousness and can lead to
death. If running in a confined or
partially-enclosed area, the air may
contain a dangerous amount of
carbon monoxide. To keep exhaust
fumes from building up, always
provide adequate ventilation.
Always use a battery-powered
carbon monoxide detector when
running the generator. If you begin
to feel sick, dizzy, or weak while
using the generator, shut it off and
get to fresh air immediately. See a
doctor. You may have carbon
monoxide poisoning.
WARNING:
When this generator is used to
supply a building wiring system:
generator must be installed by a
qualified electrician and connected to a
transfer switch as a separately derived
system. The generator shall be
connected through a transfer switch
that switches all conductors other than
the equipment grounding conductor.
The frame of the generator shall be
connected to an approved grounding
electrode. Failure to isolate the
generator from power utility can result
in death or injury to electric utility
workers.
A-iPower Corp. 10887 Commerce Way Unit A Fontana, CA 92337 USA
www.a-ipower.com 1-855-888-3598 or [email protected].