Page 21
STORAGE
It is recommended to start and run the generator for
30 minutes, every 30 days. If this is not possible,
refer to below short term and long term storage.
Short Term Storage
Fill the tank with fresh gasoline and add gasoline
stabilizer. Drain the carburetor float bowl.
1 - Add a properly formulated FUEL STABILIZER to
the tank if it is not already added.
2 - Run the engine for 10-15 minutes to circulate
stabilizer throughout fuel system.
Checking and adjusting valve clearance must be
done when the engine is cold.
NOTICE
0.003~0.004 inch
0.08~0.11 mm
0.003~0.004 inch
0.08~0.11 mm
10-12 N·M
10-12 N·M
Intake Valve
Exhaust Valve
Valve
Clearance
Torque
GENERATOR MAINTENANCE
Make certain that the generator is kept clean and
stored properly. Only operate the unit on a flat, level
surface in a clean, dry operating environment.
DO NOT
expose the unit to extreme conditions,
excessive dust, dirt, moisture or corrosive vapours.
NOTE:
DO NOT
use a garden hose to clean the generator.
Water can enter the generator through the cooling
slots and damage the generator windings.
Use a damp cloth to clean exterior surfaces of the
generator.
Use a soft bristle brush to remove dirt and oil.
Use an air compressor 25 PSI (172 kPa) to clear dirt
and debris from the generator.
Inspect all air vents and cooling slots to ensure that
they are clean and unobstructed.
Cleaning the Spark Arrestor
1. Allow the engine to cool completely before
servicing the spark arrestor.
2. Remove 6 screws to remove the muffler cover
assembly.
3. Loosen the screw (A) to be able to remove clamp
(B) and cover plate (C).
4. Remove the spark arrestor screen (D).
5. Carefully remove the carbon deposits from the
spark arrestor screen with a wire brush.
6. Replace the spark arrestor if it is damaged.
7. Position the spark arrestor on the muffler and
replace the muffler cover with the screws
removed in step 2.
NOTE:
This product is equipped with a spark arrestor that
has been evaluated by the USDA Forest Service;
however, product users must comply with Federal,
State, and local fire prevention regulations. Check
with appropriate authorities. Contact customer
service or a qualified service center to purchase a
replacement spark arrestor.
A
B
C
D
Summary of Contents for SUA2700i
Page 26: ...Page 24 PARTS DIAGRAM PARTS DIAGRAM AND PARTS LIST SUA2700i ...
Page 31: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Page 33: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Page 61: ...Page 26 SCHÉMA DES PIÈCES SCHÉMA DES PIÈCES ET LISTE DES PIÈCES SUA2700i ...
Page 66: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...
Page 68: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...
Page 97: ...Página 27 DIAGRAMA DE PIEZAS DIAGRAMA DE PIEZAS Y LISTA DE PIEZAS SUA2700i ...
Page 102: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...
Page 104: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...