Suzhou A-hand Technology Co., Ltd. (215021)
Instruction
Address: No. 88, Tangzhuang Road, Suzhou Industrial Park, China
NO.
33
Tel: +86-512-6252-9140
http://
www.a-hand.com
only in an emergency or system crash, it is recommended!
Manual attenuation
Press the attenuation button
on the remote control, at this time stop the machine in
the following order:
1. Current reduces according to program (attenuation).
2. When the arc is extinguished, the rotation stops, the nose returns to arcing point.
3. After the arc is extinguished, the lagging air feed stops as the setting time in order to
protect the welding torch and tungsten electrode.
Emergency reset
Press
on the remote control, reset the welding, in the event of an emergency situation
or software system failure, use this key.
9
.
3 Restart
After stopping the device by the stop button in the event of an emergency, re-start a full welding cycle.