background image

A.H. Systems SAS-510-7 Log Periodic Antenna

CALCULATIONS

EMISSIONS TESTING

Individual   calibration   data   for   the   log   periodic   antenna   is   supplied   at
appropriate distances (3, and 10 meter) to comply with various emissions test
requirements.   For   emissions   measurements,   add   antenna   factor   plus   cable
loss to receiver reading in dB

V to convert to field strength in dB

V/meter. 

Field Strength(dBuV/m) = SA(dBuV) + AF(dB/m) + cable loss (dB)

SA = Spectrum Analyzer or Receiver voltage reading 

AF = Antenna Correction Factor

CL = Cable Loss in dB

IMMUNITY TESTING

For Immunity measurements, the generated electric field strength can be 
calculated by:

FS = Approximate Field Strength in (V/m)

P = Power in watts
g = Numeric Gain
d = Distance in meters

 A.H. Systems inc. – May 2014

REV C

11

Summary of Contents for SAS-510-7

Page 1: ...A H Systems SAS 510 7 Log Periodic Antenna SAS 510 7 Log Periodic Antenna Operation Manual A H Systems inc May 2014 REV C 1...

Page 2: ...Optional Equipment 5 OPERATING INSTRUCTIONS Assembly Instructions 6 Mounting Instructions 6 Operating Instructions 8 SPECIFICATIONS Specifications 9 Typical Data 10 Calculations 11 Convertion Factors...

Page 3: ...l cover the whole device under test Constructed of lightweight aluminum the SAS 510 7 Log Periodic Antenna has been manufactured to operate over a very wide bandwidth Weighing in at just 1 5 pounds th...

Page 4: ...designed to be used in the process of generating controlling and measuring high levels of electromagnetic Radio Frequency RF energy It is the responsibility of the user to assure that the device is op...

Page 5: ...an be made to your specifications Other cable types available upon request Adapters Need an Adapter We stock those as well MOUNTING ACCESSORIES AEH 510 Azimuth and elevation head to assist the test en...

Page 6: ...ization Each tripod leg is independently adjustable in angle and length to facilitate antenna height setting The tripod legs have a rubber tip on one end for indoor or hard surface use and a metal spi...

Page 7: ...ement is made from the center of the antenna radiating elements and is annotated by a measurement point sticker per ANSI C63 5 IMMUNITY TESTING MEASUREMENT POINT Measurement is made from the tip of th...

Page 8: ...ation when the elements are perpendicular to the ground To minimize impedance mismatch errors it is recommended that high quality in line attenuators be used to reduce reflections Connect the attenuat...

Page 9: ...dBi Maximum Continuous Power 1000 Watts Average Beamwidth 35 Average Beamwidth H Field 100 Impedance nominal 50W Average VSWR 1 65 1 typ 2 5 1 max Maximum Radiated Field 200 V m Connector N Type femal...

Page 10: ...A H Systems SAS 510 7 Log Periodic Antenna TYPICAL DATA A H Systems inc May 2014 REV C 10...

Page 11: ...a factor plus cable loss to receiver reading in dB V to convert to field strength in dB V meter Field Strength dBuV m SA dBuV AF dB m cable loss dB SA Spectrum Analyzer or Receiver voltage reading AF...

Page 12: ...o T T 1 25 A m dB A to dBA dBA dB A 120 E FIELD ANTENNAS LOG LINEAR POWER Correction Factor dB V m dB V AF dBm to Watts W 10 dBm 30 10 Field Strength V m 30 watts Gain numeric meters Watts to dBm dBm...

Page 13: ...issions testing for electromagnetic compatibility EMC requires the measurement of electric field E field strength which is compared with a limit level The output voltage of an antenna is converted to...

Page 14: ...ng with the delivery of the product by A H Systems The remedy set forth herein shall be the only remedy available to the buyer and in no event shall A H Systems be liable for direct indirect incidenta...

Reviews: