TECHNICAL MANUAL 

620020E05 

 

 

 

Due to the continuous products improvement, the indications of the present manual can be modified without previous warning and in any 

case are a contract commitment. The present information publishing does not represent resignation of intellectual property or patent. 

Copyright 

2009-2010 S.A. Sistel -E 08211 BARCELONA

 

 

Pag.  5

  

1.2   Precautions against damage to people 

 

Do  not  work  on  the  product  with  the 
power on. 

To avoid electrical discharge, this product must not be handled with 
the  system  powered  on  and  in  any  case  it  may  not  be  operated 
without protective covers. 
 

 

1.3   Precautions against damage to the product 

 

Do  not  insert  /  unplug  cards  or  other 
electronic elements when powered up 
 

The  connection/disconnection  of  the  I/O’s  when  plugged  to  the 
power could produce a sequence of connections that could damage 
electronic components which had been previously connected to their 
corresponding reference earth.  

Do not force the connection tag strips  

The connection tag strips are connected exerting a small pressure. If 
you  encounter  difficulty  to  plug  them  this  may  mean  that  they  are 
upside down or not aligned. If they  are forced, besides the damage 
to the strip you can cause damages on the electronics. 

Secure the ground connections quality. 

All  the  ground  connections  must  be  star-type  and  with  the  suitable 
section.  Loop  ground  connections  are  potential  receptor  antennas 
with capacity to generate important current peaks. 

Use  suitable  packing  material  for 
transportation 

An  electronic  module  with  a  lot  of  fragile  components  should  be 
transported with a good protection packaging. A collision can cause 
damages that could appear long time after the start up. 

Do  not  install  this  product  near  heat 
sources,  strong  vibrations  or  high 
humidity  that  exceeds  the  technical 
specifications. 
 

Check  that  the  product  works  without  vibrations  that  exceed  the 
maximum  levels  specified,  and  which  could  damage  its  integrity  or 
cause a contact to become disconnected.  The product should work 
without  humidity  and  in  the  temperature  range  detailed  in  the 
technical specifications. 

 
 

2. Limits of the guarantee 

 

 

Products are supplied to the latest available development state at the time of manufacture. Should there 
be any future changes for functional or productive improvements of the products; the manufacturer does 
not hold any obligation to reprocess at no charge the products that have been already manufactured to 
upgrade them to the latest versions. 

 

All the products supplied by S.A. Sistel have passed all established quality controls as well as the EMC 
(Electromagnetic Compatibility Checks). The manufacturer cannot be held responsible for any damage 
produced by defective manipulation, installation or incompatibility with other products. 

 

The products’ guarantee will only be in force when the installation has been done in accordance  with 
the technical prescriptions in this manual and the settled general standards: Low Voltage Electro Tech-
nical Regulation (or equivalent for each country) and CE regulations for the Electromagnetic Compatibil-
ity.  

 

Summary of Contents for YAV904X8

Page 1: ...Two pole 4x8 Switching Matrix YAV904X8 620020E05 Created 13 02 07 Updated 01 12 15...

Page 2: ...Sistel E 08211 BARCELONA Pag 2 This manual is related to the following product Product P N YAV904X8 Hardware version 02 Software version 01 Issued date 29 06 2010 Document History Version Issued date...

Page 3: ...4 Device electrical Characteristics 7 3 5 Block diagram 8 3 6 Connectors Jumpers 8 3 6 1 X1 Connector Device Power CAN 8 3 6 2 Jumpers 8 3 6 3 X2 Connector Relays 9 3 6 4 LEDs 9 3 7 YAV904X8 Dimensio...

Page 4: ...damaging this product products connected to it or people Only qualified and entitled 1 personnel are authorized to carry out operations of installation and routine on the devices described in this man...

Page 5: ...rtant current peaks Use suitable packing material for transportation An electronic module with a lot of fragile components should be transported with a good protection packaging A collision can cause...

Page 6: ...ells The board is organized in 4 groups of 8 bipolar relays with double contact acces to each branch therefore we have the possibility to set up different multiplexer configurations depending on the c...

Page 7: ...Device electrical Characteristics Parameter At Te 5 65 C unless otherwise specified Symbol Values Unit Min Typ Max Operating Parameters Operating voltage Vbb 18 30 VDC Operating current At 24VDC IGND...

Page 8: ...e TOFF 3 ms 3 5 Block diagram 3 6 Connectors Jumpers 3 6 1 X1 Connector Device Power CAN Pin Description 1 GND 2 24V 3 CAN Low 4 CAN High 3 6 2 Jumpers Jumper Description SW1 Address CAN bus speed and...

Page 9: ...B Bit P0H 1 75 Row D Bit P1H 1 12 Row A Bit P0L 2 44 76 Row C Bit P1L 2 13 Row A Bit P0L 2 45 Row B Bit P0H 2 77 Row C Bit P1L 2 14 Row D Bit P1H 2 46 Row B Bit P0H 2 78 Row D Bit P1H 2 15 Row A Bit...

Page 10: ...modified without previous warning and in any case are a contract commitment The present information publishing does not represent resignation of intellectual property or patent Copyright 2009 2010 S A...

Page 11: ...2 Relays 3 0x05 Time 10ms Set OUT All Relays Rx 0x155102xx 7 0x02 0x03 Relays 0 Relays 1 Relays 2 Relays 3 0x06 ASK ALL Relays Rx 0x155102xx 3 0x02 0x04 Autosend All Relays Status Tx 0x155202xx 6 0x0...

Page 12: ...D_RATE AttrValueList 0 Baudrate AttrIdList 1 NC_ATTR_START_ON_OPEN AttrValueList 1 NC_TRUE AttrIdList 2 NC_ATTR_READ_Q_LEN AttrValueList 2 0 AttrIdList 3 NC_ATTR_WRITE_Q_LEN AttrValueList 3 1 AttrIdLi...

Page 13: ...id length Status ncWrite TxHandle sizeof Transmit Transmit if Status 0 PrintStat Status ncWrite Sleep 1000 Transmit Data 0 0x02 YAV command prefix Transmit Data 1 0x01 YAV command prefix Transmit Dat...

Page 14: ...powerful tool for table top debugging of test systems or system maintenance on site The interface is very user friendly Activating a relays By clicking a relays in the panel the relays will close and...

Page 15: ...ublishing does not represent resignation of intellectual property or patent Copyright 2009 2010 S A Sistel E 08211 BARCELONA Pag 15 The name of K1 and K2 has also been changed because in his design th...

Page 16: ...label with its serial number The guarantee period is two years from invoice date 6 Install Uninstall YAV modules into from a VPC Receiver 6 1 Receiver connector 6 1 1 YAVs with 96 pin connector YAV m...

Page 17: ...property or patent Copyright 2009 2010 S A Sistel E 08211 BARCELONA Pag 17 For removing the modules unscrew and hold the module with two hands from both sides and pull straight out 6 2 Connections 6...

Page 18: ...the YAV module a CAN interface will be needed Although other CAN Interfaces can be used under the responsibility of the user 6TL recom mends using any CAN bus High Speed Interface from National Instru...

Page 19: ...onfigurable easy to expand and maintain Each modules can work independently form the tester so you can just plug each of them directly into the ITA frame of a fixture to start debugging the software w...

Page 20: ...tained in the module firmware and cannot be changed There is a different identification for each YAV module type Therefore modules of different module identification can have the same hardware address...

Page 21: ...4 B4 8 8 UP 00 1001 9 9 C1 C1 9 9 UP 00 1010 10 10 C2 C2 10 10 UP 00 1011 11 C3 C3 11 11 UP 00 1100 12 C4 C4 12 12 UP 00 1101 13 A5 13 13 UP 00 1110 14 A6 14 14 UP 00 1111 15 B5 15 15 UP 01 0000 16 B6...

Page 22: ...AV 90304 6TL_Smema_Bridge YAV90304 48 YAV90304 YAV 90304 6TL_Hipot_Switch1 YAV90304 47 YAV90304 YAV 90304 6TL_Hipot_Switch2 H710061 0 00 0000 8710061E02 H7100 61 6TL_Conveyor_Belt X H710061 H710061 1...

Page 23: ...refers to the default and standard 6TL name given by Phi6 to each module depending on his function in the 6TL platform These aliases could be changed through Phi6 Explorer edit Tags Seventh column Pl...

Page 24: ...ponsability that the product YAV904X8 Two pole 4x8 switching matrix to which this declaration relates meets the provisions of the EU Directives listed be low Electro Magnetic Compatibility EMC directi...

Page 25: ...can be modified without previous warning and in any case are a contract commitment The present information publishing does not represent resignation of intellectual property or patent Copyright 2009...

Reviews: