6TL YAV904X8 Manual Download Page 19

 

TECHNICAL MANUAL 

620020E05 

 

 

 

Due to the continuous products improvement, the indications of the present manual can be modified without previous warning and in any case 

are a contract commitment. The present information publishing does not represent resignation of intellectual property or patent. 

Copyright 

2009-2010 S.A. Sistel -E 08211 BARCELONA

 

 

Pag.  19

  

8. YAV modules overview 

 
The use of YAV modules provides a real technical, economical and logistic advantage against 
all  other  classic  instrumentation  solutions.  YAV  modules  are  the  solution  for  typical  practical 
problems  that  occur  while  designing  test  platforms.  They  provide  a  considerably  test  system 
performance  increase.  The  minimal  amount  of  connections  and  wiring  length  reduction  main-
tains the best quality and integrity of the signals and provides a short assembly and wiring time. 
 
Being a combination of hardware modules and software drivers, the implementation of the YAV 
modules  in  your  test  system  is  very  fast.  When  connected,  the  modules  are  immediately 
operative.  YAV  modules  make  your  test  system  very  flexible,  re-configurable,  easy  to  expand 
and maintain. Each modules can work independently form the tester so you can just plug each 
of them directly into the ITA frame of a fixture to start debugging the software without the need 
of using the test platform. While the tester is being used to test PCBAs you have the advantage 
to debug or build any new configuration in a few minutes. 
 
Can  bus  control  has  a  big  advantage;  it  provides  all  the  control  and  power  supply  signals  to 
power the YAV modules with just 4 wires. Therefore the modules can be mounted in any part of 
the  test  system  or  test  fixture.  The  Can  bus  transmission  speed  might  be  lower  than  the  one 
available in parallel buses, but it is at least 100 times faster than the speed needed to control all 
the available functions in each of our YAV modules. 
 

8.1  YAV modules common information 

8.1.1 SW1 DIP switch functionality 

 
The eight switches contained in SW1 are covering the following functionalities: 
 

  Set CAN bus speed 

  Set module address 

ON

1  2  3  4  5  6  7  8

ON=1

OFF=0

 

8.1.2 CAN bus communication speed. 

 
Switches 1 and 2 set the CAN communication speed: 
  
Select  50Kb/s  to  communicate  with  Phi6  and  all  6TL  modules.  All  devices  communicating 
through  the  CAN  network  must  have  the  same  speed  configured  in  order  to  communicate 
properly. 
 
 
 
 

Summary of Contents for YAV904X8

Page 1: ...Two pole 4x8 Switching Matrix YAV904X8 620020E05 Created 13 02 07 Updated 01 12 15...

Page 2: ...Sistel E 08211 BARCELONA Pag 2 This manual is related to the following product Product P N YAV904X8 Hardware version 02 Software version 01 Issued date 29 06 2010 Document History Version Issued date...

Page 3: ...4 Device electrical Characteristics 7 3 5 Block diagram 8 3 6 Connectors Jumpers 8 3 6 1 X1 Connector Device Power CAN 8 3 6 2 Jumpers 8 3 6 3 X2 Connector Relays 9 3 6 4 LEDs 9 3 7 YAV904X8 Dimensio...

Page 4: ...damaging this product products connected to it or people Only qualified and entitled 1 personnel are authorized to carry out operations of installation and routine on the devices described in this man...

Page 5: ...rtant current peaks Use suitable packing material for transportation An electronic module with a lot of fragile components should be transported with a good protection packaging A collision can cause...

Page 6: ...ells The board is organized in 4 groups of 8 bipolar relays with double contact acces to each branch therefore we have the possibility to set up different multiplexer configurations depending on the c...

Page 7: ...Device electrical Characteristics Parameter At Te 5 65 C unless otherwise specified Symbol Values Unit Min Typ Max Operating Parameters Operating voltage Vbb 18 30 VDC Operating current At 24VDC IGND...

Page 8: ...e TOFF 3 ms 3 5 Block diagram 3 6 Connectors Jumpers 3 6 1 X1 Connector Device Power CAN Pin Description 1 GND 2 24V 3 CAN Low 4 CAN High 3 6 2 Jumpers Jumper Description SW1 Address CAN bus speed and...

Page 9: ...B Bit P0H 1 75 Row D Bit P1H 1 12 Row A Bit P0L 2 44 76 Row C Bit P1L 2 13 Row A Bit P0L 2 45 Row B Bit P0H 2 77 Row C Bit P1L 2 14 Row D Bit P1H 2 46 Row B Bit P0H 2 78 Row D Bit P1H 2 15 Row A Bit...

Page 10: ...modified without previous warning and in any case are a contract commitment The present information publishing does not represent resignation of intellectual property or patent Copyright 2009 2010 S A...

Page 11: ...2 Relays 3 0x05 Time 10ms Set OUT All Relays Rx 0x155102xx 7 0x02 0x03 Relays 0 Relays 1 Relays 2 Relays 3 0x06 ASK ALL Relays Rx 0x155102xx 3 0x02 0x04 Autosend All Relays Status Tx 0x155202xx 6 0x0...

Page 12: ...D_RATE AttrValueList 0 Baudrate AttrIdList 1 NC_ATTR_START_ON_OPEN AttrValueList 1 NC_TRUE AttrIdList 2 NC_ATTR_READ_Q_LEN AttrValueList 2 0 AttrIdList 3 NC_ATTR_WRITE_Q_LEN AttrValueList 3 1 AttrIdLi...

Page 13: ...id length Status ncWrite TxHandle sizeof Transmit Transmit if Status 0 PrintStat Status ncWrite Sleep 1000 Transmit Data 0 0x02 YAV command prefix Transmit Data 1 0x01 YAV command prefix Transmit Dat...

Page 14: ...powerful tool for table top debugging of test systems or system maintenance on site The interface is very user friendly Activating a relays By clicking a relays in the panel the relays will close and...

Page 15: ...ublishing does not represent resignation of intellectual property or patent Copyright 2009 2010 S A Sistel E 08211 BARCELONA Pag 15 The name of K1 and K2 has also been changed because in his design th...

Page 16: ...label with its serial number The guarantee period is two years from invoice date 6 Install Uninstall YAV modules into from a VPC Receiver 6 1 Receiver connector 6 1 1 YAVs with 96 pin connector YAV m...

Page 17: ...property or patent Copyright 2009 2010 S A Sistel E 08211 BARCELONA Pag 17 For removing the modules unscrew and hold the module with two hands from both sides and pull straight out 6 2 Connections 6...

Page 18: ...the YAV module a CAN interface will be needed Although other CAN Interfaces can be used under the responsibility of the user 6TL recom mends using any CAN bus High Speed Interface from National Instru...

Page 19: ...onfigurable easy to expand and maintain Each modules can work independently form the tester so you can just plug each of them directly into the ITA frame of a fixture to start debugging the software w...

Page 20: ...tained in the module firmware and cannot be changed There is a different identification for each YAV module type Therefore modules of different module identification can have the same hardware address...

Page 21: ...4 B4 8 8 UP 00 1001 9 9 C1 C1 9 9 UP 00 1010 10 10 C2 C2 10 10 UP 00 1011 11 C3 C3 11 11 UP 00 1100 12 C4 C4 12 12 UP 00 1101 13 A5 13 13 UP 00 1110 14 A6 14 14 UP 00 1111 15 B5 15 15 UP 01 0000 16 B6...

Page 22: ...AV 90304 6TL_Smema_Bridge YAV90304 48 YAV90304 YAV 90304 6TL_Hipot_Switch1 YAV90304 47 YAV90304 YAV 90304 6TL_Hipot_Switch2 H710061 0 00 0000 8710061E02 H7100 61 6TL_Conveyor_Belt X H710061 H710061 1...

Page 23: ...refers to the default and standard 6TL name given by Phi6 to each module depending on his function in the 6TL platform These aliases could be changed through Phi6 Explorer edit Tags Seventh column Pl...

Page 24: ...ponsability that the product YAV904X8 Two pole 4x8 switching matrix to which this declaration relates meets the provisions of the EU Directives listed be low Electro Magnetic Compatibility EMC directi...

Page 25: ...can be modified without previous warning and in any case are a contract commitment The present information publishing does not represent resignation of intellectual property or patent Copyright 2009...

Reviews: