![6TL YAV90090 Manual Download Page 9](http://html.mh-extra.com/html/6tl/yav90090/yav90090_manual_3044812009.webp)
9
Ethernet to CAN Gateway YAV90090 620090E06
The cabling for this connector should be constructed according to the characteristics
described:
Description
Value
Nom. Diff. Characteristic Impedance
100 ohms (+10 ohms, -15 ohms)
Nom. Inductance @ 10 kHz
0.47 uH/meter
Nom. Capacitance
– Conductor To Conductor @
10 kHz
41.0 pF/meter
Nom. Capacitance
– Conductor To Other
Conductor & Shield @ 10 kHz
65.6 pF/meter
Nom. Velocity of Propagation
74%
Nom. Conductor DC Resistance @ 20C
14.57 ohms / 100 meters
Nom. Outer Shield DC Resistance @ 20C
1.7 ohms / 100 meters
Max. Operating Voltage
– UL
30 V RMS
Pin
Function
1
Tx+
2
Tx-
3
Rx+
4
-
5
-
6
Rx-
7
-
8
-
2.5.4 Mode Dip switch SW2
With the DIP switch 2 the user can change the IP address from the device, select if the
communication is unicast or multicast, change the IP multicast address and select to use
the default Ethernet settings or to use the user configured settings.
By default, YAV90090 will have the following IP addresses:
•
IP address: 192.168.18.55
•
Net mask: 255.255.255.0
•
Gateway address: 192.168.18.10
•
Multicast IP address: 224.0.0.5
NOTE:
YAV90090 can handle any other IP configuration, contact with 6TL
Engineering for more information.