background image

User manual EasyTop 2 kW  audio system 

                    

 

 

   4SeasonsSpa

®

 

 

                                                                                                                                    

 

 

 

 

Fig 2.1 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Fig 2.2 

 
 
 

 
 
 
 
 

 
 

Summary of Contents for AUGUSTA

Page 1: ...MANUAL 2 kW EasyTop with 2 jet pumps and audio system AUGUSTA JULIA LISA ...

Page 2: ...e to all safety instructions before filling the spa and connecting it to the power supply This manual is an integral part of the product and therefore must be kept for future reference along with your warranty Chapter 1 Safety information Chapter 2 Installation instructions Chapter 3 Spa Operation Chapter 4 Using the Spa Chapter 5 Draining the Spa Chapter 6 DIP SWITCHES and LOW LEVEL configuration...

Page 3: ...has been damaged or is missing 1 5 Water Temperature The water in a spa should never exceed 39 C Water temperatures between 37 C and 39 C are considered safe for a healthy adult Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes Immersion in water that is too hot may cause your body temperature to rise by a few degrees from the normal body temperature o...

Page 4: ...ot rely on it completely always add a small amount of chlorine or other kind of suitable steriliser in order to make sure that the water is completely sterilised The spa may become wet and slippery and has sharp or non yielding parts Ensure therefore that you know how to enter and leave the spa safely before you start using the spa Always ensure someone is present to offer assistance should the us...

Page 5: ...and well ventilated The spa has to be installed on a dry surface In other words the frame of the spa should not be in contact with water Make sure that the spa is installed a few centimetres above the level of the balcony or floor to ensure that no water will remain under the spa during or after a rain shower The ventilation of the frame is important for its life span There should be at least 10 c...

Page 6: ...User manual EasyTop 2 kW heater audio system 4SeasonsSpa 6 Fig 2 1 Fig 2 2 ...

Page 7: ...n somebody uses the spa Do not use rain or surface water to fill the spa Ensure the water level is always on or around the indicated level on the skimmer A water level that is not sufficiently high will cause air to enter the pipes and the pump which voids the warranty It is recommended that a garden hose is used to fill the spa through the skimmer This will facilitate starting the pumps as it wil...

Page 8: ...z 32 A high current connection Double phase 230 V 50 60 Hz 2 x 16 A zero grounded 2 x 16 A high current connection The unused connections of the control box can let water flow through For safety reasons and to prevent personal injuries and material damage these connections should be covered with approved covers This way the inside of the control box will not come into contact with water that is sp...

Page 9: ...is solid the heater is working You are able to switch between LC and HC with Dip Switch SW1 on the board of the control box Dip Switch SW1 OFF High Current ON Low Current The following pages will show you the possible connection for this configuration Please notice the difference between high and low current and the way the heater is connected 2 1 kW 3 3 kW 5 2 kW Also pay extra attention during w...

Page 10: ... L3 N V1 V2 L1 L2 L3 M5 M6 M9 M8 M11 M13 HEATER L2 N J4 J5 J6 L3 Phase1 Neutral Ground Heater Ground Heater Neutral CD Heater Phase Power Supply 1 x 32A HC High Current Configuration To have this configuration you have to put the first dip switch in position OFF on J2 L1 L2 L3 N V1 V2 L1 L2 L3 M5 M6 M9 M8 M1 M13 HEATER L2 N J4 J5 J6 L3 Phase1 Neutral Ground Heater Phase Heater Ground Heater Neutra...

Page 11: ...op 2 kW heater audio system 4SeasonsSpa 11 Power Supply 2 x 16A HC High Current Configuration To have this configuration you have to put the first dip switch in position OFF on Heater Ground Heater Neutral Heater Phase ...

Page 12: ...omy function active Economy function in stand by Filter or Purge function active Filter or Purge function in stand by 3 1 Activating the control system display Check the following before operating the spa Ensure the spa is filled with water Ensure all valves are open Ensure the water flow through the pipes is not obstructed The temperature of the water used to fill the spa is in general lower than...

Page 13: ...e By using the arrow keys you can adjust the water temperature to the desired temperature The newly selected water temperature will be shown on the display for five seconds confirming the new settings After this period the display will start to show the current temperature again The EasyTop controller can be used to set the water temperature to a value between 15 and 40 C The temperature can be ad...

Page 14: ...Programming at 14 00 a three hour filtering cycle needs to be run starting at 19 00 Calculation of the delay until start 19 00 14 00 5 hours On the keypad set the duration of the filtering cycle 3 hours and the delay until start in this case 5 hours The overall effect will be that the first filtering cycle lasting three hours will start at 19 00 the next at 7 00 and the next at 19 00 etc Note if t...

Page 15: ...de BOO 3 6 Inverting the display This function is used to invert the direction of the display so as to make it easy to read from the outside Due to the type of software installed it is possible to activate the function as following Press and hold for 5 seconds the Filter Purge The function is disabled in the same way The function is also disabled by switching the pack off 3 7 Temperature unit This...

Page 16: ...n from entering the spa accidentally c Regulating the Jet power The pumps force a large amount of water through the jets It is possible to add more force to the jet by adding air to the water The air supply is regulated using 4 air valves controls two for each pump Turn the tap to the left to open the air supply or to the right to close the air supply You will only see an effect when the pumps are...

Page 17: ...th a powerful water jet In the LOW LEVEL setting a warning can be activated that displays a clean filter CF warning on the display every week By pressing any button this warning is removed It is recommended to renew the filter cartridge every year Your spa dealer will be able to provide you with special cleaning products for your filter cartridge Never use regular soap as it will have a negative i...

Page 18: ... value of the water and adjust if necessary Keep the pH between 7 0 and 7 5 At this pH value disinfecting products will work best The total alkaline value should be kept between 80 en 120 ppm mg l Record the values in a log book for your records 7 Free chlorine should be kept at a minimum of 1 5 mg l 8 Every two months the night before draining the spa add some Anti scale to your spa water and lea...

Page 19: ...nitizer levels are high When water begins to flow out of the hose open the air relief valve located on filter lid Your spa will drain except for a small quantity left in the foot well This can be removed with a sponge and bucket Once empty clean with a damp cloth and do not use cleaning products To finish push garden hose forward and turn outer ring clockwise remove garden hose and attach safety c...

Page 20: ...the pumps Ask you dealer how much to use this depends on the brand anti freeze you use 2 Empty the spa as described in section 5 Emptying the spa The spa plumbing and pumps should not contain any water This cannot be achieved just by regularly emptying the spa 3 Loosen all connections in the mechanical room and release them All connections have to be greased with acid free Vaseline and stored in a...

Page 21: ...ition ON Position OFF 1 Low Current High Current 2 10 button keypad 8 button keypad 3 Blower installed Blower not installed 4 Pump 1 one speed Pump 1 two speed 5 Pump 2 one speed Pump 2 two speed 6 Pump 3 installed Pump 3 not installed 7 Circulation pump installed Circulation pump not installed 8 Ozon active during filtering Ozon always on Once having modified the position of the switches on the d...

Page 22: ... will appear Up Down keys modify values Duration Press Filter key to display next parameter System will reset after last parameter Display As table below Default values in bold Parameter Display Value Meaning 1 Single intensity Light LIx 2 Light with two intensity levels 0 None Remote heater RHx 1 Remote heater On 1 Filtering cycle Filtering FCx 2 Purge cycle 0 Disable Clean filter warning CLEx 1 ...

Page 23: ... L Brown J1 2 N Blue J1 3 Yellow Green Phase Neutral Ground Circulation Pump 230VAC 1 FLA J7 1 L Brown J7 2 N Blue J7 3 Yellow Green Phase Neutral Ground Ozone Generator 230VAC 1 A J8 1 L Brown J8 2 N Blue J8 3 Yellow Green Phase Neutral Ground Aux1 230VAC 1 A J9 1 L Brown J9 2 N Blue J9 3 Yellow Green Phase Neutral Ground Aux2 230VAC 1 A J10 1 L Brown J10 2 N Blue J10 3 Yellow Green Phase Neutral...

Page 24: ... service FLO The pressure switch flow switch does not detect the movement of water when the circulation pump is on pump 1 if the circulation pump is not installed Check that the low level settings of the circulation pump and the pressure switch correspond to the configuration of the spa Check that the level of the water is sufficient and that the valves are open Clean the filter If the problem per...

Page 25: ...e white plastic part in the diverter or air valve and apply also some acid free Vaseline Hard water lime will inhibit smooth turning of the diverters and air valves Not all jets are working Ensure all pumps operate at high speed Ensure all diverters are in the intermediate position so all jets receive adequate water Ensure all jets are open it is possible to open and close each jet separately Wate...

Page 26: ...une Seek Up 5 IR port 16 Clock Set 6 Intro Station Presets 6 11 17 Local 7 Random play 18 Scan 8 Repeat 19 Radio Band 9 Pause Play Preset 4 20 Front Panel Latch 10 Disc Changer Prev Disc 21 CD Eject Inside Door 11 Disc Changer Next Disc 2 Pop up Speakers waterproof 50 Watt Sub woofer 5 25 woofer 100 Watt Floating remote control 1 13 12 11 9 8 7 6 5 4 3 2 14 15 16 17 18 19 10 20 0 ...

Page 27: ...indicates front bias R1 to R15 indicates rear bias Setting The Clock Hold the SET button 16 for 2 seconds until the first digit of the time flashes Use the TUNE SEEK UP button 15 or TUNE SEEK Down 14 to set the Hour Press the SET button to toggle the display between Clock and Radio Modes Opening and Closing the front panel Place thumb on the front panel latch button 20 Firmly depress the button wh...

Page 28: ...st stations will be selected during SEEK or Scan Changing Tuner for US or European Frequencies The radio is factory set to US frequency steps For European use disconnect power and reset switch on the bottom of the radio to the European setting Power must be off or the reset must be used Using The CD MP3 WMA Player Open the front panel Insert the disc label side up partially into the slot and it wi...

Page 29: ...irst track in each Directory will play CD Changer If an MCD6 changer is installed pressing the INTRO button will show SCN in the left side of the display The main display will show which CD is playing In this mode the first 10 seconds of each track of each CD in the magazine will play Pressing INTRO for 3 seconds will change the display to CDC and play the first ten seconds of the first track on e...

Page 30: ... Unit will not turn on Check Power Connections and voltage to unit Check Fuses Red 10A Yellow 1A Check front panel for stuck buttons Press reset button see page 9 CD will not play Check disk for Damage Try another CD MP3 disc Check for stuck buttons Press reset button Volume up stops but indication continues to 31 Check available voltage This indicates insufficient wire size on power connection Er...

Page 31: ...User manual EasyTop 2 kW heater audio system 4SeasonsSpa 31 ...