The table below lists the specifications of the outputs available. It also shows the connections on the board and
their function for each output.
Output
Voltage, current
External connector
Strain relief
Board connections
Connection
function
Pump1, 2 speed
230VAC, 6.5 FLA
J11-1 (HI): Brown
J11-2 (N): Blue
J11-3 (Lo): Black
J11-4: Yellow/Green
High speed
Neutral
Low speed
Ground
Pump2, 2 speed
230VAC, 6.5 FLA
J13-1 (HI): Brown
J13-2 (N): Blue
J13-3 (Lo): Black
J13-4: Yellow/Green
High speed
Neutral
Low speed
Ground
Pump3, 1 speed
230VAC, 6.5 FLA
J12-1 (L): Brown
J12-2 (N): Blue
J12-3: Yellow/Green
Phase
Neutral
Ground
Blower
230VAC, 6 A
J1-1 (L): Brown
J1-2 (N): Blue
J1-3: Yellow/Green
Phase
Neutral
Ground
Circulation Pump
230VAC, 1 FLA
J7-1 (L): Brown
J7-2 (N): Blue
J7-3: Yellow/Green
Phase
Neutral
Ground
Ozone Generator
230VAC, 1 A
J8-1 (L): Brown
J8-2 (N): Blue
J8-3: Yellow/Green
Phase
Neutral
Ground
Aux1
230VAC, 1 A
J9-1 (L): Brown
J9-2 (N): Blue
J9-3: Yellow/Green
Phase
Neutral
Ground
Aux2
230VAC, 1 A
J10-1 (L): Brown
J10-2 (N): Blue
J10-3 Yellow/Green
Phase
Neutral
Ground
Light
12 VAC, 2 A
Bayonet connector on cable
J3 - MTA 100
Power Supply
230 VAC, 1x16A
230 VAC, 2x16A
230 VAC, 3x16A
J2-1 (L1): Brown
J2-2 (L2): Black
J2-3 (L3): Grey
J2-4 (N): Blue
J2-5 Yellow/Green
Phase1
Phase2
Phase3
Neutral
Ground
1 phase Heater
230 VAC, 16 A
J4 (L2): Brown
J5 (N): Blue
M13: Yellow/Green
Phase
Neutral
Ground
2 phases Laing Heater
230 VAC, 16 A
J4 (L2): Brown
J5 (N): Blue
J6 (L3): Black
M13: Yellow/Green
Phase1
Neutral
Phase2
Ground
M32
M25
M20
M25
M20
M20
M20
M20
M20
M20
M20