Rated power 

100W per channel, 200W bridged 

Output bandwidth 

50 Hz – 20 kHz 

SNR 

>80 dB 

THD + N 

0.1% @ rated power 

 

Audio 

 

 

Frequency response 

 

 

 

Local BGM 

50 Hz – 20 kHz 

 

 

Messages, network streaming 

100 Hz – 12 kHz 

 

Analog input- output latency 

< 10 ms (stand-alone system) 

 

Network audio stream format 

24 kHz sampling, ADPCM compressed 

 

Message file input format 

24 kHz, 16 bit, mono WAV 

 

DSP features 

HP/LP filter, multipoint parametric EQ, delay 

Mechanical 

 

 

Dimensions (HxWxD) 

80 x 52 x 28 cm 

 

Weight (full config, without batteries) 

29 kg 

 

Housing material 

Steel / ABS 

 

IP rating 

IP 30 

 

Mounting 

Wall-mounted box 

 

 

Network system

 

 

Max. number of devices in the network 

255 

Max. number of zones 

255 

Max. total system output power 

102 kW 

Number of simultaneous network audio channels  2 
Network audio transmission latency 

0.3 ms per device 

Local network 

 

 

Architecture 

Master-slave, up to 16 slave devices per C500 main unit 

 

Connection 

3 x L-Net port, RJ-45, powered daisy chain, digital audio & control data 

 

Cabling 

X-over FTP CAT5e (or higher) 

 

Current consumption 

max. 500 mA (up to 8 slave devices) per L-Net port,  

 

Max. length of local bus 

 

 

 

default 

250 m 

 

 

with twisted-pair extender 

500 m 

Global network 

 

 

Architecture 

Peer-to-peer, up to 255 C500 main units 

 

Connection 

2 x G-Net port, RJ-45, powered redundant ring, digital audio & control data 

 

Cabling 

X-over FTP CAT5e (or higher) / multimode optical fiber 

 

Current consumption 

max. 500 mA per port, reserved only for network extenders 

 

Max. distance between devices 

 

 

 

default 

250 m 

 

 

with copper extenders 

750 m 

 

 

with fiber extenders 

2500 m 

Summary of Contents for Compact 500

Page 1: ...0 Voice Evacuation System It explains how to operate the Compact 500 and how to interpret indications This operation manual is addressed to end users as well as technical personnel such as service tec...

Page 2: ...system 4 Network system 4 3 2 1 Global network G Net 4 3 2 2 Local network L Net 5 4 Front Panel 6 LED indicators 6 4 1 1 POWER 6 4 1 2 EVAC 6 4 1 3 FAULT 7 4 1 4 POWER SUPPLY 7 4 1 5 SYSTEM FAULT 7 4...

Page 3: ...he Compact 500 is to provide public address functionalities such as background music public announcements or general paging Compact 500 is extremely scalable due to its network capabilities and create...

Page 4: ...NCE and RESET input 8 x GPI 8 x GPO Up to 6 loudspeaker lines with EOL monitoring 100W or 200W maximum power per line 2 analog balanced audio inputs Integrated Fireman Microphone with priority Access...

Page 5: ...500 operation manual Author DD Page 5 of 15 3 2 2 Local network L Net L Net daisy chain topology is dedicated for peripheral devices of the main unit such as remote microphone stations L Net is used t...

Page 6: ...dicates the operating status of the C500 Continuous system is powered and ready Blinking fast system is booting not ready for full operation 4 1 2 EVAC Indicates that the system is in the Voice Alarm...

Page 7: ...charger o Battery resistance too high o Temperature fault o Charger communication fault 4 1 5 SYSTEM FAULT Indicates system fault of the C500 main unit where The CPU or program execution is stopped or...

Page 8: ...d by one of following audio signals Continuous LIVE EVAC Blinking slow EVAC Message 4 1 7 2 Yellow Indicates that the zone is transmitting an ALERT message and or is in fault state Continuous Zone fau...

Page 9: ...ed in the configuration settings 4 2 4 RESET Press to clear your current zone selection 4 2 5 FUNCTION button Press and hold the FUNCTION button to enable Access level 2 In access level 2 you are able...

Page 10: ...nel one by one forcing the backup amplifier to engage and take over the channel where the fault is simulated The sequence will be displayed on the front panel ZONE LEDs NOTE the backup amplifier test...

Page 11: ...essage ALERT message SILENCE RESET fireman mic with PTT button Fireman microphone Integrated Fireman Mic with priority and electrical monitoring Power supply equipment Built in power supply system EN...

Page 12: ...29 kg Housing material Steel ABS IP rating IP 30 Mounting Wall mounted box Network system Max number of devices in the network 255 Max number of zones 255 Max total system output power 102 kW Number...

Page 13: ...Hacousto Holland bv Industrieweg 87 2651BC Berkel Rodenrijs 4EVAC Compact 500 operation manual Author DD Page 13 of 15 8 Marking...

Page 14: ...Hacousto Holland bv Industrieweg 87 2651BC Berkel Rodenrijs 4EVAC Compact 500 operation manual Author DD Page 14 of 15...

Page 15: ...651BC Berkel Rodenrijs 4EVAC Compact 500 operation manual Author DD Page 15 of 15 M A D E I N T H E N E T H E R L A N D S 4EVAC is a trade name of Hacousto Holland bv Industrieweg 87 2651BC Berkel Rod...

Reviews: