![3Ware 720-0186-00 Manual Download Page 121](http://html1.mh-extra.com/html/3ware/720-0186-00/720-0186-00_manual_3239008121.webp)
Enclosure Object and Element Commands
www.3ware.com
114
/c
x
/e
x
show
This command is used with the 9690SA controller. For the 9650SE and CCU
enclosure, simply drop the prepended controller name in the command and
use /e
x
.
This command shows summary information on the specified enclosure
c
x
/e
x
.
This report consists of several parts, depending on the available elements of
the enclosures. Typically, the summary consists of the
Enclosure
section
listing the set of enclosures, a
Fan
section listing the set of fans, a
Temperature Sensor
section listing of the set of temperature sensor, a
Power
Supply
section listing the set of power supplies, and a
Slot
section listing the
set of slots.
Example:
//localhost> /c0/e0 show
Encl Status
---------------------------
/c0/e0 -
Fan Status State Step RPM Identify
------------------------------------------------------------
fan0 OK ON 1 2670 Off
fan1 OK ON 1 9500 Off
fan2 OK ON 1 8540 Off
fan3 OK ON 1 2830 Off
fan4 OK ON 1 9120 Off
fan5 OK ON 1 8330 Off
TempSensor Status Temperature Identify
--------------------------------------------------------
temp0 OK 41C(105F) Off
temp1 OK 38C(100F) Off
temp2 OK 34C(93F) Off
temp3 OK 38C(100F) Off
temp4 OK 38C(100F) Off
temp5 OK 34C(93F) Off
temp6 NOT-INSTALLED - Off
temp7 NOT-INSTALLED - Off
PowerSupply Status State Voltage Current Identify
---------------------------------------------------------------------------
pwrs0 OK on OK OK Off
pwrs1 OK on OK OK Off
Slot Status VPort Identify
--------------------------------------------------
slot0 OK /c0/p0 Off
slot1 NO-DEVICE - Off
slot2 OK /c0/p1 Off
slot3 OK /c0/p2 Off
slot4 OK /c0/p3 Off
slot5 OK /c0/p4 Off
slot6 OK /c0/p5 Off
slot7 OK /c0/p6 Off
slot8 OK /c0/p7 Off
slot9 OK /c0/p8 Off
slot10 OK /c0/p9 Off
slot11 NO-DEVICE - Off