7
3
Prepare motor for installation:
•
When changing the adapter set (SW50 or SW70): Press the safety catch with a screwdriver and pull off the shaft adapter at the same time.
>
fig. 3.1 / 3.2
Then replace limit switch adapter and put shaft adapter on adapter holder.
>
fig. 3.3 / 3.4
•
Push limit switch adapter flush against motor head.
>
fig. 3.5 / 3.6
•
Push the motor into the roller shutter shaft without using force (never knock it in). The fold of the shaft must lie over the recess in the shaft adapter.
>
fig. 3.7 / 3.8
•
Make sure that the roller shutter shaft is flush with the limit switch adapter motor head.
>
fig. 3.9 / 3.10
4
Mount bearings:
•
Remove old wall bearing on motor side (left or right installation possible).
•
Mount motor bearing at this point.
•
Make sure that the roller shutter motor with the shaft unit sits horizontally in the roller shutter box.
5
Mount motor with shaft unit:
•
Insert the motor head (with the entire shaft unit) into the motor bearing and secure it with the supplied safety pin.
3.5
Limit switch adapter
Motor head
3.6
3.7
Shutter shaft
3.8
3.9
3.10
Fold
Recess
wrong
right
3.1
Safety catch
3.2
Shaft adapter
Click
3.4
3.3
Replace limit switch
adapter
INSTALLATION INSTRUCTIONS
3T-MOTORS Tubular motors
| Installation instructions