3Shape TRIOS S3P-2 Setup Manual Download Page 5

5

ENGLISH

• 

Touch screen

: Touch-enabled screen for real-time display of scanning 

results generated by the TRIOS software, and for interacting with the 
TRIOS software .

•  The 

system standby button

 (S17) is on the back of the monitor .

•  In the bottom (S18), there is a power socket (S19), a network (LAN)  

connector (S20), and a fuse drawer (S21) . In the top of the backpack 
(Figure 7), the dongles are inserted, see description below .  

•  USB wireless dongle (allows communication between scanner and 

computer or cart)

•  USB license dongle (access to 3Shape Software)
•  USB wifi dongle (for connecting cart to wifi network)
•  Bluetooth dongle (for connecting the cart to Bluetooth devicesas 

keyboard and mouse)

• 

USB port (only MOVE+): 

The MOVE+ has a USB port (S29) .

The friction of the arm of the MOVE/MOVE+ cart that holds the scanner  
and the display can be adjusted . The corresponding tool is provided with  
the system . (Figure 8) 

Step 1:

 Move the arm to the top-most position .

Step 2:

 Insert the tool into the hole on the bottom side of the arm, 

located approx . half way along the arm .

Step 3:

 Turn the tool clockwise to increase friction, anticlockwise  

to reduce friction .

Step 4:

 Adjust friction so that the monitor is steady (does not sink,  

does not go up) in the following scenarions:
•  Scanner is positioned in scanner holder
•  Scanner is not positioned in scanner holder

IMPORTANT NOTICE

Maximum current available for the USB port is 200 mA .

System S3P furthermore comprises (Figure 3 and 4):

Pod, PS3-4

 (S22) (Figure 3):

•  A mount for the scanner
•  A USB wireless dongle for the PC (S23)
•  A USB license dongle

Pod with electronics, PS3-2 (Figure 4):

•  A mount for the scanner with several connection sockets . On one side, 

there is a single socket for the scanner . On the other side, there are two 
connection sockets for the Ethernet cable to the PC and for the external 
medical power supply, respectively .

•  A USB license dongle

4.7 Setting up TRIOS

It is recommended that unpacking, assembly and connection of the TRIOS 
IOS System be performed by TRIOS authorized technical service personnel . 

It is recommended to fully charge batteries for the scanner before use .

CAUTION

If the system has just been delivered from a cold environ-
ment, let it adjust to room temperature to avoid internal 
condensation and to allow for proper calibration .

CAUTION

Examine all parts of the system . Look for physical damage, 
loose parts or signs of wear that could interfere with proper 
use and functionality . Contact your service provider if there 
is visible damage or malfunctioning .

System S3A (MOVE/MOVE+ cart) only

Please follow the steps below for assembling TRIOS IOS system (Figure 5):

Step 1:

 Place the MOVE/MOVE+ cart optimally in relation to the patient 

chair and your work position . (S24)

Step 2:

 Attach the protection tip to the TRIOS scanner if not already  

in place . (S25)

Step 3:

 Insert a battery fully into the rear of the scanner (S26) or insert 

the TRIOS 4 cord into rear of scanner (S27) and connect the scanner 
cable to the scanner connection socket on the MOVE/MOVE+ cart 
behind the screen below the hinge (S28)

Step 4:

 Place the scanner in its designated scanner holder on the 

MOVE/MOVE+ cart (Figure 2, S15) .

Step 5:

 Connect the MOVE/MOVE+ cart end of the power cable to the 

socket in the bottom of the MOVE/MOVE+ cart’s base . (Figure 2, S19)

Step 6:

 Connect the power cable to a grounded power outlet . Ensure 

that the MOVE/MOVE+ cart is placed so it does not block the switch on 
the mains socket outlet . To isolate the MOVE/MOVE+ cart and thus the 
scanner from supply mains, unplug the flexible power cord from mains .

System S3P (Pod) only

Please follow the steps below for assembling TRIOS IOS system (Figure 6):

Before you start:

 Place the pod on a flat and horizontal surface optimally 

in relation to the patient chair and your work position . Attach the protec-
tion tip to the TRIOS scanner if not already in place . For the wired scanner, 
we recommend not to place the scanner onto the pod at this time yet, so 
that it is easier to lift the pod while connecting cables in the following . 

For the wired scanner (for the wireless scanner, begin with 

step 6

)

Step 1:

 Connect the Ethernet cable to the pod . The cable goes into the left  

connection socket on the back side of the pod (the side that has two 
connection sockets) . If you need to release the Ethernet cable, press  
on the small tab on the top of the connector .

Step 2:

 Connect the power supply to the pod . This cable goes into the con-

nection socket next to the Ethernet cable described in the previous step . 
•  To connect - push the plug into socket . There are red orien tation  

dots on the socket and the plug that should match .

•  To disconnect - pull on the outer release sleeve .
The indicator light will light green .

Step 3:

 Connect the TRIOS 4 cord to the scanner connection socket on 

the front side of the pod (the side that has only one connection socket) .
•  To connect - push the plug into the socket . There is a red orien tation 

dot on the plug that should point upwards .

•  To disconnect - pull on the outer release sleeve .
Now all connections to the pod are established, and you can place the 
scanner onto the pod .

Summary of Contents for TRIOS S3P-2

Page 1: ...04 2021 3Shape TRIOS Safety and Setup Guide S3P 2 S3P 8 S3A 10 S3A 14 S3A 18 S3A 22...

Page 2: ...rmity EU 3ShapeTRIOSA SherebydeclaresthattheTRIOSobservestheprovisionsof Medical Device Regulation EU 2017 745 MDR Restriction of Hazardous Substances in Electrical and Electronic Equipment Directive...

Page 3: ...Electronic Equipment Directive 2012 19 EU Radio Equipment Directive 2014 53 EU CAUTION EU only CE marking for connected products Further products which are connected to this unit must also bear the CE...

Page 4: ...t in PC 3 scanner batteries and a scanner battery charger You can find the figures in the final section of this guide All system variants comprise Handheld TRIOS intraoral scanner S3 2 S1 and S2 Wired...

Page 5: ...our service provider if there is visible damage or malfunctioning System S3A MOVE MOVE cart only Please follow the steps below for assembling TRIOS IOS system Figure 5 Step 1 Place the MOVE MOVE cart...

Page 6: ...is due Other messages include a reminder to mount the scanning tip Please make sure the scanning tip is mounted on the scanner Calibration A calibration of the handheld TRIOS scanner is required befo...

Page 7: ...pendent on local reg ulations and the configuration of the product 5 Safety and Warnings 5 1 Prerequisites CAUTION Read all instructions carefully including all warnings and caution notices You must c...

Page 8: ...it should immediately be calibrated before further use If calibration fails please contact your technical service provider See this guide s instructions on calibrating the handheld scanner WARNING If...

Page 9: ...wer cable network cable and the smart cord must never be subjected to pulling stress Spilled liquids WARNING Do not bring liquids such as beverages near the TRIOS IOS system Do not spill liquids on th...

Page 10: ...S3P pod only WARNING Before each patient make sure any PC connected to the system and its peripherals are disinfected It is recom mended to use medical grade peripherals e g keyboards and mice that ca...

Page 11: ...manual for more information CAUTION New tips must be cleaned and sterilized high level disinfected before using them for the first time CAUTION A class B Vacuum autoclave according to EN 13060 is requ...

Page 12: ...iod of use IMPORTANT NOTICE All surfaces that the protection tip comes in contact with particularly the scanner tube and its optical window must always be cleaned and disinfected before attaching the...

Page 13: ...the correct rating and type 250 V T 3 15 A H must be used To replace the fuses first mount them in the drawer then insert the drawer back into the slot and push all the way in until the tabs click ba...

Page 14: ...3Shape TRIOS A S Holmens Kanal 7 1060 Copenhagen Denmark 10030970A April 2021 Copyright 3Shape TRIOS A S Let s change dentistry together More information at 3Shape com...