background image

8

9

ENGLISH

ENGLISH

• To achieve the best fi t, the elasticized edge of the hood or headcover

 

faceseal should come in

contact with your face under the chin and above the ears.

 S-403 only:

 The S-403 is designed to

be worn with the inner shroud tucked into other protective clothing. Tuck the inner shroud fully into
your work clothing. Leave the outer shroud draped over your shoulders. 

S-600, S-700, and S-800 Series

• Adjust the S-950 suspension as necessary to achieve a comfortable fi t (Fig. 10a & 10b). An optional

chin strap (S-958) is available for additional comfort and stability. See 

Replacement Parts and

Accessories

 section of this 

User Instruction

 for additional information.

• Leave the outer shroud draped over your shoulders. If using the S-807 or S-805 Hood, pull the long

outer shroud down over clothing and tie tightly, but comfortably at the sides. 

• Adjust the airfl ow of the S-950 Premium Head Suspension for wearing comfort by rotating the

Airfl ow Adjustment Cover (S-955) according to Fig. 11. While wearing, the airfl ow may be directed
primarily to the front visor (Fig. 12) or split to provide more airfl ow to the top of the head (Fig. 13). 

 

WARNING

1. 

Failure to follow these instructions may result in serious injury.

a. Do not use these products for eye and face protection. When exposed to eye and face hazards

(e.g. impact hazards) select and wear appropriate protection. 

b. Do not use these products around heat, fl ames, or sparks. Select and wear appropriate

protection when exposed to sparks and/or fl ames. In case of intended use in explosive
atmospheres, contact 3M. 

2.  The S-Series hoods and headcovers are one component of an approved respiratory protection

system. Always read and follow all 

User Instructions

 supplied with your 3M PAPR Blower Unit

or Supplied Air Unit in order to ensure correct system operation. 

Failure to do so may reduce

respirator performance, overexpose you to contaminants, and may result in injury, 
sickness, or death.

With the respirator in operation, enter the contaminated area, breathing normally. Keep the air supply 
hose or PAPR assembly away from equipment, vehicles, and other physical and chemical hazards. 
1.  Airborne contaminants which can be dangerous to your health include those that are so small you

may not be able to see or smell them.

2. 

Do not

 wear this respirator to enter areas where:

a. Atmospheres are oxygen defi cient. 
b. Contaminant concentrations are unknown.
c. Contaminant concentrations are Immediately Dangerous to Life or Health (IDLH).
d. Contaminant concentrations exceed the maximum use concentration (MUC) determined using

the Assigned Protection Factor (APF) for the specifi c respirator system or the APF mandated by
specifi c government standards, whichever is lower. See 

APF

 section of this 

User Instruction.

3.  Leave the contaminated area 

before

 reaching inside or removing the hood or headcover. Do not

remove the respirator or reach your hand into the hood or headcover in areas where the air is
contaminated. 

4.  Leave the contaminated area immediately if any of the following conditions occur: 

a. Any part of the system becomes damaged.
b. Airfl ow into the respirator decreases or stops.

Fig. 11

Fig. 12

Fig. 13

Fig. 9

Fig. 8

S-100, S-300, S-400, and S-500 Series:

• Pull the hood or headcover over your head so that the visor is directly in front of your face.
• Pull the suspension fi rmly onto your head. The suspension should feel tight but comfortable. The

comfort pad (i.e. sweatband) should be worn around your forehead just above the brow.

Headgear with plastic suspensions only 

(all models except S-103 and S-403): If your hood or

headcover has a plastic suspension it may be adjusted as necessary to achieve a comfortable fi t
(Fig. 8). The headband of the plastic suspension should be worn around your forehead and the
crown strap should be positioned on top of the head, not around the back of the head (Fig. 9). 

NOTE: 

The fabric suspension in the S-103 and S-403 is not adjustable. 

Fig. 10a

Fig. 10b

• Insert the suspension into the hood (see 

Assembly

 section of this

 User Instruction

).

• Pull the hood over your head so that the visor is directly in front of your face.
• If using the optional chin strap, place the elastic strap under your chin and pull the ends of the strap

to adjust the tightness. 

• If your hood has an inner bib (shroud), tuck the inner shroud fully into your work clothing. 

3.  Complete any fi nal performance checks required according to the 

User Instructions

 for your PAPR or

Supplied Air Unit.

Entering and Exiting the Contaminated Area

Summary of Contents for Versaflo S Series

Page 1: ...403S S 403L S 433S S 433L S 533S S 533L S 605 S 607 S 707 3Versaflo S Series Hoods and Headcovers User Instructions for Important Before use the wearer must read and understand these User Instruction...

Page 2: ...nstructions 4 Unpacking 4 Assembly 4 Donning Fitting 7 Entering and Exiting the Contaminated Area 9 Inspection Maintenance 10 Replacement Parts and Accessories 10 S 950 Premium Head Suspension 11 Peel...

Page 3: ...expose you to contaminants and may result in injury sickness or death Always correctly position the S 100 S 300 S 400 and S 500 Series hoods and loose fitting facepieces on the head Users should be cl...

Page 4: ...and applicable NIOSH Cautions and Limitations OPERATING INSTRUCTIONS Unpacking Inspect the package contents for shipping damage and ensure all components are present The product should be inspected b...

Page 5: ...r 3M hood or headcover Follow the User Instructions for your 3M PAPR or Supplied Air Unit to properly assemble don and fit your specific air source Complete all necessary performance checks as describ...

Page 6: ...irborne contaminants which can be dangerous to your health include those that are so small you may not be able to see or smell them 2 Do not wear this respirator to enter areas where a Atmospheres are...

Page 7: ...ent points 2 Secure the S 954 Size Reducing Comfort Pad to the suspension according to Fig 17a d The two long slots in the size reducing comfort pad hook over the large top hooks on the premium head s...

Page 8: ...u to quickly peel off covers as they become difficult to see through reducing the number of times you must stop working to reapply covers Note S 920S peel offs use with S 133S S 133SB S 333S S 433S S...

Page 9: ...ool Fig 20c SPECIFICATIONS Contact 3M Technical Service for additional technical specifications e g weight materials of construction etc Note The S Series hoods and headcovers contain no components ma...

Page 10: ...g Pad S 922 Peel Off S 757 37301 Assembly Contains Painter s Hood with Inner Shroud S 950 Premium Head Suspension S 955 Airflow Adjustment Cover S 954 Size Reducing Pad S 922 Peel Off S 855 Assembly C...

Page 11: ...t apply to expendable consumables accessories or fabric components such as but not limited to filters cartridges face seals shrouds hoods and head covers and visors Warranty time periods for specified...

Reviews: