background image

2

3

ENGLISH

ENGLISH

 

WARNING

FOREWORD

Contact Information

Read all instructions and warnings before using. Keep these 

User Instructions

 for reference. If you have 

questions regarding these products contact 3M Technical service. 

In United States:
Website: www.3M.com/OccSafety
Technical Service: 1-800-243-4630

In Canada:
Website: www.3M.com/CA/occsafety
Technical Service: 1-800-267-4414

System Description

The 3M™ Versafl o™ S-Series hoods and headcovers are designed to be used with certain 3M 
breathing tubes and Powered Air-Purifying Respirators or Supplied Air Units to form a respirator 
system. 
The S-100 and S-300 series headcovers (i.e. loose fi tting facepieces) and the S-400 and S-500 series 
hoods have a wide-view window (visor) and an elasticized faceseal. The S-403 has an added inner 
bib or shroud which is worn tucked into work clothing. The hoods and headcovers are held in place 
with an adjustable, non-replaceable plastic integrated suspension (S-133, S-133B, S-333, S-433, 
and S-533) or a sewn-in elastic suspension (S-103 and S-403). There are different sizes and fabrics 
available and all headcovers and hoods are supplied fully assembled, ready for use. 
The S-600, S-700, and S-800 series hoods incorporate a neck collar or inner bib with an outer shroud 
and a wide-view visor. They are available in a variety of fabrics. The S-800 series hoods have sealed 
seams to help prevent liquid permeation through the thread holes. The S-600, S-700, and S-800 series 
hoods use the S-950 Premium Head Suspension. The S-950 suspension is easily removable and can 
be adjusted by the user for fi t and airfl ow comfort. 

Properly selected, used, and maintained respirators help protect against certain airborne 
contaminants by reducing concentrations in the wearer’s breathing zone below the Occupational 
Exposure Limit (OEL). It is essential to follow all instructions and government regulations on 
the use of this product, including wearing the complete respirator system during all times of 
exposure, in order for the product to help protect the wearer. 

Misuse of respirators may result in 

overexposure to contaminants and lead to sickness or death.

 For proper use, see supervisor, 

refer to the product 

User Instructions

 or contact 3M Technical Service.

List of Warnings within these 

User Instructions

This product helps protect against certain airborne contaminants. 

Misuse may result in sickness or death. 

For proper use, see 

supervisor, 

User Instructions

 or call 3M in U.S.A., 1-800-243-4630. 

In Canada, call Technical Service at 1-800-267-4414.

 

WARNING

 WARNING

1.  This product helps protect against certain airborne contaminants.

 Misuse may result in

sickness or death.

 For proper use, see supervisor, 

User Instructions

 or call 3M in U.S.A., 

1-800-243-4630. In Canada, call Technical Service at 1-800-267-4414.

2. 

Failure to follow these instructions

 may reduce respirator performance, overexpose you to

contaminants, and 

may result in injury, sickness, or death.

• Always correctly position the S-100, S-300, S-400, and S-500 Series hoods and loose-fi tting

facepieces on the head. 

• Users should be clean-shaven where the respirator’s faceseal (S-100, S-300, S-400, and

S-500 series products) comes into contact with their face. 

• Always tuck the inner shroud of the S-403, S-607, S-707, and S-807 hood into your work

clothes. 

• Always pull the S-950 premium head suspension fully through the opening in the S-600, 

S-700, and S-800 series hoods. 

• Do not use with parts or accessories other than those manufactured by 3M as described in

these 

User Instructions

 or on the NIOSH approval label for this respirator. 

• The S-Series hoods and headcovers are one component of an approved respiratory protection

system. Always read and follow all 

User Instructions

 supplied with your 3M PAPR Blower Unit

or Supplied Air Unit in order to ensure correct system operation. 

3.  Do not use these products for eye and face protection. When exposed to eye and face hazards

(e.g. impact hazards) select and wear appropriate protection. 

Failure to do so may result in

serious injury. 

4.  Do not use these products around heat, fl ames, or sparks. Select and wear appropriate

protection when exposed to sparks and/or fl ames. 

Failure to do so may result in serious

injury. 

In case of intended use in explosive atmospheres, contact 3M Technical Service. 

Limitations of Use

1.  Do not wear this respirator to enter areas where:

a. Atmospheres are oxygen defi cient.
b. Contaminant concentrations are unknown.
c. Contaminant concentrations are Immediately Dangerous to Life or Health (IDLH).
d. Contaminant concentrations exceed the maximum use concentration (MUC) determined using

the Assigned Protection Factor (APF) for the specifi c respirator system or the APF mandated by
specifi c government standards, whichever is lower. See 

APF

 section of this

 User Instruction.

2.  These products may offer limited splash protection against certain chemicals. Consult a qualifi ed

industrial hygienist and the applicable Chemical Permeation Guide(s) to determine suitability of
these products for your specifi c environment. Note, only the S-800 series hoods have sealed seams
to help prevent liquid permeation through thread holes. For additional information, contact 3M
Technical Service. 

Respirator Program Management 

Occupational use of respirators must be in compliance with applicable health and safety standards. By
law, US employers must establish a written respiratory protection program meeting the requirements 
of the OSHA Respiratory Protection Standard 29 CFR 1910.134 and any applicable OSHA substance 
specifi c standards. In Canada, CSA standard Z94.4 requirements must be met and/or requirements of 
the applicable jurisdiction, as appropriate. For additional information on this standard, contact OSHA 
at www.OSHA.gov. The major sections of 1910.134 are listed here for reference. Consult an industrial 
hygienist or call 3M Technical Service with questions concerning applicability of these products to your 
job requirements.

!

Summary of Contents for Versaflo S Series

Page 1: ...403S S 403L S 433S S 433L S 533S S 533L S 605 S 607 S 707 3Versaflo S Series Hoods and Headcovers User Instructions for Important Before use the wearer must read and understand these User Instruction...

Page 2: ...nstructions 4 Unpacking 4 Assembly 4 Donning Fitting 7 Entering and Exiting the Contaminated Area 9 Inspection Maintenance 10 Replacement Parts and Accessories 10 S 950 Premium Head Suspension 11 Peel...

Page 3: ...expose you to contaminants and may result in injury sickness or death Always correctly position the S 100 S 300 S 400 and S 500 Series hoods and loose fitting facepieces on the head Users should be cl...

Page 4: ...and applicable NIOSH Cautions and Limitations OPERATING INSTRUCTIONS Unpacking Inspect the package contents for shipping damage and ensure all components are present The product should be inspected b...

Page 5: ...r 3M hood or headcover Follow the User Instructions for your 3M PAPR or Supplied Air Unit to properly assemble don and fit your specific air source Complete all necessary performance checks as describ...

Page 6: ...irborne contaminants which can be dangerous to your health include those that are so small you may not be able to see or smell them 2 Do not wear this respirator to enter areas where a Atmospheres are...

Page 7: ...ent points 2 Secure the S 954 Size Reducing Comfort Pad to the suspension according to Fig 17a d The two long slots in the size reducing comfort pad hook over the large top hooks on the premium head s...

Page 8: ...u to quickly peel off covers as they become difficult to see through reducing the number of times you must stop working to reapply covers Note S 920S peel offs use with S 133S S 133SB S 333S S 433S S...

Page 9: ...ool Fig 20c SPECIFICATIONS Contact 3M Technical Service for additional technical specifications e g weight materials of construction etc Note The S Series hoods and headcovers contain no components ma...

Page 10: ...g Pad S 922 Peel Off S 757 37301 Assembly Contains Painter s Hood with Inner Shroud S 950 Premium Head Suspension S 955 Airflow Adjustment Cover S 954 Size Reducing Pad S 922 Peel Off S 855 Assembly C...

Page 11: ...t apply to expendable consumables accessories or fabric components such as but not limited to filters cartridges face seals shrouds hoods and head covers and visors Warranty time periods for specified...

Reviews: