background image

Step 5: Complete plumbing connections on SGLP-RO System

NOTE: Refer to installation diagram above.

1)  Install installation parts onto the SGLP-RO unit and close the inlet and sample water 

valves.

2)  Connect inlet water supply to the SGLP-RO system inlet using either the quick connect 

fitting or the supplied hose barb (if using hose). 

3)  Install drain line from permeate pump brine out port to a drain.
4)  Run tubing from the SGLP-RO outlet to the Duke oven. 

NOTE: The SGLP-RO comes with two outlet fittings to accommodate different types 

of tubing. One fitting is a ¼” barb as shown in the diagram above. This fitting should be 

used with flexible tubing. A 3/8” stem x ¼” quick connect fitting is also included for rigid 

poly tubing.

“Brine Out”

Port

RO Outlet to Duke Oven

3/8”

Blue Tubing

Outlet Tee

Water Sample

Valve Assembly

Feedwater from the

Beverage Outlet on the

Subway® Filter System

RO Membrane Plug

“Brine In”

Port

1/4” Red Tubing

(To Drain)

Red

Tubing

(To Bottom

of RO

Membrane

Cartridge)

Using Push-In Fittings

(1) Pre-filter Sediment & Carbon
(2) RO Membrane

To Attach Tubing

Push tubing in as far as it will go.  Tubing must be inserted past

o-ring and hit backstop.  Pull tube to ensure it is secured.

To Release Tubing

Push in grey collet to release tubing.  With collet held,

pull tubing straight out.

1

1

2

2

Remove the red tubing from the fitting before 

completely removing the RO Membrane

6

Summary of Contents for SGLP-RO

Page 1: ...Model SGLP RO Reverse Osmosis System Quick Installation Guide Note Installer please leave with owner operator 3M Water Filtration Products...

Page 2: ...ollow all safety information contained in these instructions prior to installation and use of the 3M Water Filtration Products SGLP RO Reverse Osmosis System Retain these instructions for future refer...

Page 3: ...elief valve Where a booster pump is installed on a water system you MUST install an appropriate pressure regulating valve and regulate water pressure to 80psi Contact a plumbing professional if you ar...

Page 4: ...stem for inlet and outlet tubing connections 3 Allow 3 clearance below the system for cartridge replacement 4 If desired a mounting bracket template is included in the installation manual NOTE Mountin...

Page 5: ...et valve on the existing beverage and ice filter system 2 Run tubing from the filter system outlet to the SGLP RO using the appropriate fittings and tubing not included Tee Fitting Not Included To SGL...

Page 6: ...above This fitting should be used with flexible tubing A 3 8 stem x quick connect fitting is also included for rigid poly tubing Brine Out Port RO Outlet to Duke Oven 3 8 Blue Tubing Outlet Tee Water...

Page 7: ...e the plug from the RO Membrane drain fitting by pushing down on collet while pulling plug out 3 Insert red reject tube into membrane drain fitting 4 Insert RO Membrane into filter head Be sure that t...

Page 8: ...LIMITED TO ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR ARISING OUT OF A COURSE OF DEALING CUSTOM OR USAGE OF TRADE This warranty does not cover labor If th...