background image

Step 1: Unpack the SGLP-RO System

Check that all of the parts listed below are included in the packaging. Should any parts be 

missing, please contact 3M at (866) 990-9785.

Item Description

1

Tank and Bracket Assembly (incl. Permeate Pump)

2

ScaleGard™ PreFilter (Part # 5570613)

3

ScaleGard™ RO Membrane (Part #5598729)

4

Water Sample Valve Assembly

5

1’ Length of 3/8” Tubing (not shown)

6

10’ Length of Red Tubing (not shown)

7

Adapter – Stem X Barb (1/4” x 1/4”)

8

Adapter – Stem X Barb (3/8” x 1/4”)

9

Reducer – Stem X Quik Connect (3/8” x 1/4”) 

10

Filter Plug

1

2

3

10

4

8

9

7

NOTICE (continued):

To reduce the risk associated with property damage due to water leakage or flooding:

• 

Where a booster pump is installed on a water system, you MUST install an appropriate pressure relief 

valve.  Pressure relief valve must be maintained and inspected every 6 months.  Contact a plumbing 

professional if you are uncertain how select/install/maintain a pressure relief valve.

• 

Where a booster pump is installed on a water system, you MUST install an appropriate pressure 

regulating valve and regulate water pressure to <80psi.  Contact a plumbing professional if you are 

uncertain how select/install/maintain a pressure regulating valve.

• DO NOT

 install in direct sunlight or outdoors.

• DO NOT

 install near water pipes which will be in path of a drilling tool when selecting the position to 

mount the bracket.

• 

Mount filter in such a position as to prevent it from being struck by other items used in the area of 

installation.

• Ensure that the location and fasteners will support the weight of the system when installed and full of 

water.

• 

Ensure all tubing and fittings are secure and free of leaks.

• DO NOT

 install unit if collet is missing. Contact 3M™ Water Filtration Products if collets are missing from 

any fittings.

• 

Use compatible flexible tubing with ‘push in connections’ (such as PEX tubing, PE tubing, PP tubing).

• DO NOT

 install with rigid piping (such as copper, aluminum, stainless steel, chrome plated, or anodized 

tubing).

IMPORTANT NOTES:

• Failure to follow instructions will void warranty.

3

Summary of Contents for SGLP-RO

Page 1: ...Model SGLP RO Reverse Osmosis System Quick Installation Guide Note Installer please leave with owner operator 3M Water Filtration Products...

Page 2: ...ollow all safety information contained in these instructions prior to installation and use of the 3M Water Filtration Products SGLP RO Reverse Osmosis System Retain these instructions for future refer...

Page 3: ...elief valve Where a booster pump is installed on a water system you MUST install an appropriate pressure regulating valve and regulate water pressure to 80psi Contact a plumbing professional if you ar...

Page 4: ...stem for inlet and outlet tubing connections 3 Allow 3 clearance below the system for cartridge replacement 4 If desired a mounting bracket template is included in the installation manual NOTE Mountin...

Page 5: ...et valve on the existing beverage and ice filter system 2 Run tubing from the filter system outlet to the SGLP RO using the appropriate fittings and tubing not included Tee Fitting Not Included To SGL...

Page 6: ...above This fitting should be used with flexible tubing A 3 8 stem x quick connect fitting is also included for rigid poly tubing Brine Out Port RO Outlet to Duke Oven 3 8 Blue Tubing Outlet Tee Water...

Page 7: ...e the plug from the RO Membrane drain fitting by pushing down on collet while pulling plug out 3 Insert red reject tube into membrane drain fitting 4 Insert RO Membrane into filter head Be sure that t...

Page 8: ...LIMITED TO ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR ARISING OUT OF A COURSE OF DEALING CUSTOM OR USAGE OF TRADE This warranty does not cover labor If th...

Reviews: